Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2024 |
Principal Product | Wastewater Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $1,000,000-$5,000,000 |
# of Employees | 20 |
Plant Area (Sq.Ft.) | 350,347 |
Annual Production | 1,864,491 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $187,831 | 3,636,144 | kWh | $0.05 |
Electricity Demand | $55,779 | 8,428 | kW-months/year | $6.62 |
Electricity Fees | $552 | - | $ | - |
Natural Gas | $15,201 | 1,370 | MMBtu | $11.10 |
Other Gas | $2,574 | 1 | MMBtu | $2,574.00 |
TOTAL ENERGY COSTS | $287,379 | |||
RECOMMENDED SAVINGS* | $81,971 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $59,516 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #1 | Water Usage | Water Disposal | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Fuel Oil #1 | Water Usage | Water Disposal | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $9,834 Cost: - |
$1,089 | 21,060 | $15,035 | 2,272 | $(-6,290) | (-182) | - | - | - | - | - | - | - | - |
$1,089 21,060 kWh |
$15,035 2,272 kW-months/year |
$(-6,290) (-182) MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $12,621 Cost: $12,700 |
$(-5,101) | (-98,673) | $(-895) | (-136) | - | - | $9,437 | 1,840 | $9,180 | 1,840 | - | - | - | - |
$(-5,101) (-98,673) kWh |
$(-895) (-136) kW-months/year |
- - MMBtu |
$9,437 1,840 Tgal |
$9,180 1,840 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,018 Cost: $8,430 |
$1,440 | 27,857 | $253 | 38 | - | - | - | - | - | - | $118 | - | $207 | - |
$1,440 27,857 kWh |
$253 38 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$118 - $ |
$207 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $24,521 Cost: $7,100,000 |
$20,863 | 403,534 | $3,658 | 553 | - | - | - | - | - | - | - | - | - | - |
$20,863 403,534 kWh |
$3,658 553 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $32,977 Cost: $336,971 |
$39,881 | 771,717 | - | - | - | - | - | - | - | - | $(-6,904) | - | - | - |
$39,881 771,717 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$(-6,904) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $81,971 Cost: $7,458,101 |
$58,172 | 1,125,495 | $18,051 | 2,727 | $(-6,290) | (-182) | $9,437 | 1,840 | $9,180 | 1,840 | $(-6,786) | - | $207 | - | $58,172 1,125,495 kWh |
$18,051 2,727 kW-months/year |
$(-6,290) (-182) MMBtu |
$9,437 1,840 Tgal |
$9,180 1,840 Tgal |
$(-6,786) - $ |
$207 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $59,516 Cost: $7,445,401 |
$62,184 | 1,203,108 | $3,911 | 591 | - | - | - | - | - | - | $(-6,786) | - | $207 | - | $62,184 1,203,108 kWh |
$3,911 591 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$(-6,786) - $ |
$207 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #1 | Water Usage | Water Disposal | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Fuel Oil #1 | Water Usage | Water Disposal | Personnel Changes | Primary Raw Material |