Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1991
Principal Product PVC PIPE AND FITTINGS
NAICS n/a
SIC 3084 - Plastics Pipe
Sales $5,000,000-$10,000,000
# of Employees 130
Plant Area (Sq.Ft.) 0
Annual Production 109,500,000 Pieces
Production Hrs. Annual 8,736
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $788,939 19,365,475 kWh $0.04
LPG $68,378 6,432 MMBtu $10.63
TOTAL ENERGY COSTS $857,317
RECOMMENDED SAVINGS* $36,164 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $36,164
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,045
Cost:
$4,157
$3,045 74,736 $3,045
74,736
kWh
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$550
Cost:
$1,831
$550 13,482 $550
13,482
kWh
03: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$4,864
Cost:
$1,500
$4,864 112,837 $4,864
112,837
kWh
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$3,887
Cost:
-
$3,887 95,252 $3,887
95,252
kWh
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,153
Cost:
$11,146
$2,153 52,755 $2,153
52,755
kWh
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,903
Cost:
$1,450
$1,903 46,600 $1,903
46,600
kWh
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$19,532
Cost:
$60,000
$19,532 478,605 $19,532
478,605
kWh
08: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING Savings:
$230
Cost:
-
$230 5,569 $230
5,569
kWh
TOTAL RECOMMENDED Savings:
$36,164
Cost:
$80,084
$36,164 879,836 $36,164
879,836
kWh
TOTAL IMPLEMENTED Savings:
$36,164
Cost:
$80,084
$36,164 879,836 $36,164
879,836
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage