Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1993
Principal Product Aircraft Components
NAICS n/a
SIC 3585 - Refrigeration And Heating Equipment
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 68,000
Annual Production 0 Units
Production Hrs. Annual 5,148
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $275,423 4,153,576 kWh $0.07
Natural Gas $18,360 3,752 MMBtu $4.89
TOTAL ENERGY COSTS $293,783
RECOMMENDED SAVINGS* $54,639 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $17,572
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,474
Cost:
$6,866
$7,474 113,130 $7,474
113,130
kWh
02: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$8,660
Cost:
$9,225
$8,660 108,441 $8,660
108,441
kWh
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$576
Cost:
$128
$576 8,792 $576
8,792
kWh
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$516
Cost:
$476
$516 7,913 $516
7,913
kWh
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$3,647
Cost:
$8,906
$3,647 55,100 $3,647
55,100
kWh
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,031
Cost:
$1,450
$2,031 30,774 $2,031
30,774
kWh
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$4,420
Cost:
$4,440
$4,420 66,530 $4,420
66,530
kWh
08: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$780
Cost:
$350
$780 11,723 $780
11,723
kWh
09: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$26,535
Cost:
$24,550
$26,535 - $26,535
-
kWh
TOTAL RECOMMENDED Savings:
$54,639
Cost:
$56,391
$54,639 402,403 $54,639
402,403
kWh
TOTAL IMPLEMENTED Savings:
$17,572
Cost:
$21,662
$17,572 265,534 $17,572
265,534
kWh