Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1994
Principal Product Solar Control Products
NAICS n/a
SIC 3231 - Products Of Purchased Glass
Sales $10,000,000-$50,000,000
# of Employees 135
Plant Area (Sq.Ft.) 100,000
Annual Production 80,000,000 Thousand Feet
Production Hrs. Annual 6,864
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $174,009 2,666,764 kWh $0.07
Natural Gas $182,205 27,215 MMBtu $6.70
TOTAL ENERGY COSTS $356,214
RECOMMENDED SAVINGS* $25,389 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,304
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,526
Cost:
$431
$2,526 38,980 - - $2,526
38,980
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$872
Cost:
$2,543
$872 13,482 - - $872
13,482
kWh
-
-
MMBtu
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,828
Cost:
$1,964
$2,828 43,376 - - $2,828
43,376
kWh
-
-
MMBtu
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$811
Cost:
$775
$811 12,603 - - $811
12,603
kWh
-
-
MMBtu
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,078
Cost:
$500
$1,078 16,706 - - $1,078
16,706
kWh
-
-
MMBtu
06: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$3,288
Cost:
$10,000
$3,288 50,703 - - $3,288
50,703
kWh
-
-
MMBtu
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$8,164
Cost:
$1,000
- - $8,164 1,220 -
-
kWh
$8,164
1,220
MMBtu
08: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$2,997
Cost:
$3,600
$2,997 45,721 - - $2,997
45,721
kWh
-
-
MMBtu
09: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE Savings:
$2,825
Cost:
$2,600
- - $2,825 422 -
-
kWh
$2,825
422
MMBtu
TOTAL RECOMMENDED Savings:
$25,389
Cost:
$23,413
$14,400 221,571 $10,989 1,642 $14,400
221,571
kWh
$10,989
1,642
MMBtu
TOTAL IMPLEMENTED Savings:
$7,304
Cost:
$5,438
$7,304 112,544 - - $7,304
112,544
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas