IAC logo
IAC Assessment: UF0106
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0106
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1995
Principal Product Processed Chicken
NAICS n/a
SIC 2015 - Poultry Slaughtering And Processing
Sales $50,000,000-$100,000,000
# of Employees 500
Plant Area (Sq.Ft.) 100,000
Annual Production 115,000,000 Pounds
Production Hrs. Annual 6,864
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $952,635 14,554,221 kWh $0.07
Natural Gas $202,716 32,986 MMBtu $6.15
TOTAL ENERGY COSTS $1,155,351
RECOMMENDED SAVINGS* $224,172 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $24,108
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,268
Cost:
$2,638
$7,268 135,991 - - - - $7,268
135,991
kWh
-
-
MMBtu
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$7,054
Cost:
$17,625
$7,054 111,665 - - - - $7,054
111,665
kWh
-
-
MMBtu
-
-
$
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$8,861
Cost:
$1,000
- - $8,861 1,453 - - -
-
kWh
$8,861
1,453
MMBtu
-
-
$
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$5,255
Cost:
$5,200
- - $5,255 862 - - -
-
kWh
$5,255
862
MMBtu
-
-
$
05: 2.3413 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT Savings:
$189,560
Cost:
$950,000
$361,151 6,520,809 $(-185,099) (-8,169) $13,508 - $361,151
6,520,809
kWh
$(-185,099)
(-8,169)
MMBtu
$13,508
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$925
Cost:
$1,425
$925 23,154 - - - - $925
23,154
kWh
-
-
MMBtu
-
-
$
07: 2.1212 OPERATE BOILERS ON HIGH FIRE SETTING Savings:
$5,249
Cost:
-
- - $5,249 860 - - -
-
kWh
$5,249
860
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$224,172
Cost:
$977,888
$376,398 6,791,619 $(-165,734) (-4,994) $13,508 - $376,398
6,791,619
kWh
$(-165,734)
(-4,994)
MMBtu
$13,508
-
$
TOTAL IMPLEMENTED Savings:
$24,108
Cost:
$22,688
$15,247 270,810 $8,861 1,453 - - $15,247
270,810
kWh
$8,861
1,453
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes