IAC logo
IAC Assessment: UF0114
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0114
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1995
Principal Product Aircraft Galleys
NAICS n/a
SIC 3728 - Aircraft Parts And Equipment, Nec
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 74,060
Annual Production 600 Pieces
Production Hrs. Annual 8,760
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $170,267 2,554,220 kWh $0.07
Other Gas $3,439 408 MMBtu $8.43
TOTAL ENERGY COSTS $196,541
RECOMMENDED SAVINGS* $25,212 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $16,204
#|Description Savings
Cost
Status Electricity Usage Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Other Liquid (haz) Solid Waste (non-haz)
$ kWh $ gal $ lb
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$9,049
Cost:
$2,639
$9,049 122,802 - - - - $9,049
122,802
kWh
-
-
gal
-
-
lb
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,432
Cost:
$256
$2,432 37,808 - - - - $2,432
37,808
kWh
-
-
gal
-
-
lb
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,442
Cost:
$2,820
$1,442 21,981 - - - - $1,442
21,981
kWh
-
-
gal
-
-
lb
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$94
Cost:
$300
$94 1,758 - - - - $94
1,758
kWh
-
-
gal
-
-
lb
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,847
Cost:
$350
$1,847 28,429 - - - - $1,847
28,429
kWh
-
-
gal
-
-
lb
06: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$3,128
Cost:
$5,933
$3,128 61,254 - - - - $3,128
61,254
kWh
-
-
gal
-
-
lb
07: 3.3125 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS Savings:
$5,040
Cost:
$4,450
- - $5,040 891 - - -
-
kWh
$5,040
891
gal
-
-
lb
08: 3.5311 RECOVER AND REUSE WASTE MATERIAL Savings:
$2,180
Cost:
-
- - - - $2,180 - -
-
kWh
-
-
gal
$2,180
-
lb
TOTAL RECOMMENDED Savings:
$25,212
Cost:
$16,748
$17,992 274,032 $5,040 891 $2,180 - $17,992
274,032
kWh
$5,040
891
gal
$2,180
-
lb
TOTAL IMPLEMENTED Savings:
$16,204
Cost:
$8,922
$14,024 212,485 - - $2,180 - $14,024
212,485
kWh
-
-
gal
$2,180
-
lb
Savings
Cost
$ kWh $ gal $ lb
Electricity Usage Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Other Liquid (haz) Solid Waste (non-haz)