Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1996
Principal Product Fresh Chicken Eggs
NAICS n/a
SIC 2015 - Poultry Slaughtering And Processing
Sales $5,000,000-$10,000,000
# of Employees 34
Plant Area (Sq.Ft.) 219,000
Annual Production 14,500,000 Pieces
Production Hrs. Annual 6,240
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $99,407 2,067,702 kWh $0.05
Electricity Demand $33,851 5,042 kW-months/year $6.71
LPG $5,688 786 MMBtu $7.24
TOTAL ENERGY COSTS $138,946
RECOMMENDED SAVINGS* $15,959 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $9,243
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Other Liquid (non-haz) Electricity Usage Electricity Demand Other Liquid (non-haz)
$ kWh $ kW-months/year $ gal
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$853
Cost:
-
$679 14,068 $174 26 - - $679
14,068
kWh
$174
26
kW-months/year
-
-
gal
02: 2.7122 DISCONNECT BALLASTS Savings:
$1,934
Cost:
$655
$1,744 15,533 $190 28 - - $1,744
15,533
kWh
$190
28
kW-months/year
-
-
gal
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$982
Cost:
$576
$982 20,516 - - - - $982
20,516
kWh
-
-
kW-months/year
-
-
gal
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$7,309
Cost:
$9,372
$6,097 126,905 $1,212 180 - - $6,097
126,905
kWh
$1,212
180
kW-months/year
-
-
gal
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,167
Cost:
$4,200
$1,167 24,326 - - - - $1,167
24,326
kWh
-
-
kW-months/year
-
-
gal
06: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$2,640
Cost:
$3,500
$2,213 46,014 $427 64 - - $2,213
46,014
kWh
$427
64
kW-months/year
-
-
gal
07: 3.8136 SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED Savings:
$1,074
Cost:
-
- - - - $1,074 159 -
-
kWh
-
-
kW-months/year
$1,074
159
gal
TOTAL RECOMMENDED Savings:
$15,959
Cost:
$18,303
$12,882 247,362 $2,003 298 $1,074 159 $12,882
247,362
kWh
$2,003
298
kW-months/year
$1,074
159
gal
TOTAL IMPLEMENTED Savings:
$9,243
Cost:
$10,027
$7,841 142,438 $1,402 208 - - $7,841
142,438
kWh
$1,402
208
kW-months/year
-
-
gal
Savings
Cost
$ kWh $ kW-months/year $ gal
Electricity Usage Electricity Demand Other Liquid (non-haz) Electricity Usage Electricity Demand Other Liquid (non-haz)