Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1997 |
Principal Product | Veneer boards |
NAICS | n/a |
SIC | 2435 - Hardwood Veneer And Plywood |
Sales | $1,000,000-$5,000,000 |
# of Employees | 84 |
Plant Area (Sq.Ft.) | 27,000 |
Annual Production | 310 Thousand Feet |
Production Hrs. Annual | 2,080 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $48,657 | 925,557 | kWh | $0.05 |
Electricity Demand | $19,789 | 3,668 | kW-months/year | $5.40 |
Fuel Oil #6 | $133,593 | 35,258 | MMBtu | $3.79 |
TOTAL ENERGY COSTS | $202,039 | |||
RECOMMENDED SAVINGS* | $50,571 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,344 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #6 | Administrative Changes | Primary Raw Material | By-product Production | Electricity Usage | Electricity Demand | Fuel Oil #6 | Administrative Changes | Primary Raw Material | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $380 Cost: $381 |
$267 | 4,982 | $113 | 21 | - | - | - | - | - | - | - | - |
$267 4,982 kWh |
$113 21 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $3,649 Cost: $1,000 |
- | - | - | - | $3,649 | 960 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,649 960 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $1,315 Cost: $138 |
- | - | - | - | $1,315 | 346 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,315 346 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $709 Cost: $1,839 |
$606 | 11,430 | $103 | 19 | - | - | - | - | - | - | - | - |
$606 11,430 kWh |
$103 19 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1291 ELIMINATE PRACTICE OF MIXING WASTE STREAMS |
Savings: $2,228 Cost: $2,835 |
- | - | - | - | - | - | $2,228 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,228 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6123 BURN WOOD BY-PRODUCTS FOR HEAT |
Savings: $25,000 Cost: $120,000 |
- | - | - | - | $130,000 | 33,758 | - | - | - | - | $(-105,000) | - |
- - kWh |
- - kW-months/year |
$130,000 33,758 MMBtu |
- - $ |
- - $ |
$(-105,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES |
Savings: $17,290 Cost: $10,316 |
- | - | - | - | - | - | - | - | $17,290 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$17,290 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,571 Cost: $136,509 |
$873 | 16,412 | $216 | 40 | $134,964 | 35,064 | $2,228 | - | $17,290 | - | $(-105,000) | - | $873 16,412 kWh |
$216 40 kW-months/year |
$134,964 35,064 MMBtu |
$2,228 - $ |
$17,290 - $ |
$(-105,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,344 Cost: $1,519 |
$267 | 4,982 | $113 | 21 | $4,964 | 1,306 | - | - | - | - | - | - | $267 4,982 kWh |
$113 21 kW-months/year |
$4,964 1,306 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #6 | Administrative Changes | Primary Raw Material | By-product Production | Electricity Usage | Electricity Demand | Fuel Oil #6 | Administrative Changes | Primary Raw Material | By-product Production |