Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1997 |
Principal Product | Manufactured Homes |
NAICS | n/a |
SIC | 2451 - Mobile Homes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 237 |
Plant Area (Sq.Ft.) | 130,000 |
Annual Production | 2,750 Pieces |
Production Hrs. Annual | 2,700 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $42,469 | 864,302 | kWh | $0.05 |
Electricity Demand | $32,374 | 3,475 | kW-months/year | $9.32 |
TOTAL ENERGY COSTS | $240,923 | |||
RECOMMENDED SAVINGS* | $211,553 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,578 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $346 Cost: $3,549 |
$187 | 3,810 | $159 | 17 | - | - | - | - | - | - |
$187 3,810 kWh |
$159 17 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,088 Cost: $1,850 |
$2,088 | 42,497 | - | - | - | - | - | - | - | - |
$2,088 42,497 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $1,663 Cost: - |
- | - | $1,663 | 179 | - | - | - | - | - | - |
- - kWh |
$1,663 179 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $167,231 Cost: $165,000 |
$(-1,911) | (-38,980) | $(-2,790) | (-300) | $(-1,142) | 114,240 | - | - | $173,074 | - |
$(-1,911) (-38,980) kWh |
$(-2,790) (-300) kW-months/year |
$(-1,142) 114,240 lb |
- - $ |
$173,074 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $622 Cost: $850 |
- | - | - | - | - | - | $622 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$622 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $29,205 Cost: - |
- | - | - | - | $41,805 | 1,648,285 | $(-12,600) | - | - | - |
- - kWh |
- - kW-months/year |
$41,805 1,648,285 lb |
$(-12,600) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1175 USE A DIFFERENT OR RECYCLED RAW MATERIAL |
Savings: $7,964 Cost: - |
- | - | - | - | - | - | - | - | $7,964 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$7,964 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $2,434 Cost: - |
- | - | - | - | - | - | $2,434 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$2,434 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $211,553 Cost: $171,249 |
$364 | 7,327 | $(-968) | (-104) | $40,663 | 1,762,525 | $(-9,544) | - | $181,038 | - | $364 7,327 kWh |
$(-968) (-104) kW-months/year |
$40,663 1,762,525 lb |
$(-9,544) - $ |
$181,038 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,578 Cost: $2,700 |
$2,088 | 42,497 | $1,663 | 179 | $41,805 | 1,648,285 | $(-11,978) | - | - | - | $2,088 42,497 kWh |
$1,663 179 kW-months/year |
$41,805 1,648,285 lb |
$(-11,978) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material |