Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1997 |
Principal Product | Corrugated Containers |
NAICS | n/a |
SIC | 2655 - Fiber Cans, Drums & Similar Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 850,000 Thousand Feet |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $205,518 | 5,403,869 | kWh | $0.04 |
Electricity Demand | $94,194 | 11,606 | kW-months/year | $8.12 |
Natural Gas | $204,758 | 47,507 | MMBtu | $4.31 |
TOTAL ENERGY COSTS | $505,970 | |||
RECOMMENDED SAVINGS* | $339,962 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $331,042 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,451 Cost: $11,496 |
$4,126 | 109,027 | $1,325 | 166 | - | - | - | - | - | - |
$4,126 109,027 kWh |
$1,325 166 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,786 Cost: $4,140 |
$3,702 | 97,304 | $1,084 | 133 | - | - | - | - | - | - |
$3,702 97,304 kWh |
$1,084 133 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7145 INSTALL SKYLIGHTS |
Savings: $2,447 Cost: $3,900 |
$2,447 | 64,478 | - | - | - | - | - | - | - | - |
$2,447 64,478 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $2,305 Cost: $1,300 |
$2,305 | 60,668 | - | - | - | - | - | - | - | - |
$2,305 60,668 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $427 Cost: $3,891 |
$297 | 7,913 | $130 | 16 | - | - | - | - | - | - |
$297 7,913 kWh |
$130 16 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,774 Cost: $2,000 |
$3,774 | 68,581 | - | - | - | - | - | - | - | - |
$3,774 68,581 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $1,629 Cost: $875 |
- | - | - | - | $1,629 | 823 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,629 823 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $12,422 Cost: $400 |
$12,422 | 225,674 | - | - | - | - | - | - | - | - |
$12,422 225,674 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $1,500 Cost: - |
- | - | - | - | - | - | $1,500 | 24,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,500 24,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $1,687 Cost: $2,500 |
- | - | - | - | - | - | - | - | $1,687 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$1,687 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $303,534 Cost: $400,000 |
- | - | - | - | - | - | - | - | $303,534 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$303,534 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $339,962 Cost: $430,502 |
$29,073 | 633,645 | $2,539 | 315 | $1,629 | 823 | $1,500 | 24,000 | $305,221 | - | $29,073 633,645 kWh |
$2,539 315 kW-months/year |
$1,629 823 MMBtu |
$1,500 24,000 lb |
$305,221 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $331,042 Cost: $419,962 |
$22,924 | 471,863 | $1,455 | 182 | $1,629 | 823 | $1,500 | 24,000 | $303,534 | - | $22,924 471,863 kWh |
$1,455 182 kW-months/year |
$1,629 823 MMBtu |
$1,500 24,000 lb |
$303,534 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes |