Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1998
Principal Product Juice Products
NAICS n/a
SIC 2033 - Canned Fruits And Vegetables
Sales $10,000,000-$50,000,000
# of Employees 175
Plant Area (Sq.Ft.) 142,283
Annual Production 7,000,000 Pieces
Production Hrs. Annual 6,000
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $887,518 21,898,300 kWh $0.04
Electricity Demand $92,817 42,836 kW-months/year $2.17
Natural Gas $77,385 13,863 MMBtu $5.58
TOTAL ENERGY COSTS $1,057,720
RECOMMENDED SAVINGS* $104,803 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $65,957
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,991
Cost:
$5,652
$1,820 44,256 $171 79 - - - - $1,820
44,256
kWh
$171
79
kW-months/year
-
-
MMBtu
-
-
$
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,088
Cost:
$792
$984 24,033 $104 48 - - - - $984
24,033
kWh
$104
48
kW-months/year
-
-
MMBtu
-
-
$
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$4,777
Cost:
$4,604
$4,400 107,268 $377 174 - - - - $4,400
107,268
kWh
$377
174
kW-months/year
-
-
MMBtu
-
-
$
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$980
Cost:
$1,000
$980 51,290 - - - - - - $980
51,290
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.5113 USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING Savings:
$46,067
Cost:
$116,000
$63,860 1,557,444 $5,755 2,652 $(-23,548) (-4,205) - - $63,860
1,557,444
kWh
$5,755
2,652
kW-months/year
$(-23,548)
(-4,205)
MMBtu
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$16,919
Cost:
$1,200
$16,919 376,026 - - - - - - $16,919
376,026
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$1,380
Cost:
-
- - - - - - $1,380 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$1,380
-
$
08: 3.1291 ELIMINATE PRACTICE OF MIXING WASTE STREAMS Savings:
$28,601
Cost:
$2,500
- - - - - - $28,601 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$28,601
-
$
09: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK Savings:
$3,000
Cost:
$4,000
- - - - - - $3,000 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$3,000
-
$
TOTAL RECOMMENDED Savings:
$104,803
Cost:
$135,748
$88,963 2,160,317 $6,407 2,953 $(-23,548) (-4,205) $32,981 - $88,963
2,160,317
kWh
$6,407
2,953
kW-months/year
$(-23,548)
(-4,205)
MMBtu
$32,981
-
$
TOTAL IMPLEMENTED Savings:
$65,957
Cost:
$123,852
$83,579 2,029,016 $5,926 2,731 $(-23,548) (-4,205) - - $83,579
2,029,016
kWh
$5,926
2,731
kW-months/year
$(-23,548)
(-4,205)
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $