Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1998 |
Principal Product | Filtration Systems |
NAICS | n/a |
SIC | 3569 - General Industrial Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 340 |
Plant Area (Sq.Ft.) | 295,000 |
Annual Production | 250 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $683,465 | 12,509,672 | kWh | $0.05 |
Electricity Demand | $115,909 | 25,959 | kW-months/year | $4.47 |
Natural Gas | $94,065 | 15,519 | MMBtu | $6.06 |
TOTAL ENERGY COSTS | $893,439 | |||
RECOMMENDED SAVINGS* | $83,594 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $55,356 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $5,410 Cost: - |
$5,410 | 98,476 | - | - | - | - | - | - |
$5,410 98,476 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $2,168 Cost: $648 |
$2,168 | 39,566 | - | - | - | - | - | - |
$2,168 39,566 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,651 Cost: $1,688 |
$3,243 | 58,910 | $408 | 91 | - | - | - | - |
$3,243 58,910 kWh |
$408 91 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,217 Cost: $1,396 |
$1,020 | 18,464 | $197 | 44 | - | - | - | - |
$1,020 18,464 kWh |
$197 44 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,914 Cost: $1,700 |
$6,691 | 121,630 | $2,223 | 497 | - | - | - | - |
$6,691 121,630 kWh |
$2,223 497 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,587 Cost: - |
$3,587 | 55,979 | - | - | - | - | - | - |
$3,587 55,979 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $2,133 Cost: $3,240 |
$1,434 | 26,084 | $699 | 156 | - | - | - | - |
$1,434 26,084 kWh |
$699 156 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $14,389 Cost: $18,400 |
- | - | - | - | $14,389 | 2,359 | - | - |
- - kWh |
- - kW-months/year |
$14,389 2,359 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $5,662 Cost: - |
- | - | - | - | - | - | $5,662 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,662 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $31,783 Cost: $5,000 |
- | - | - | - | - | - | $31,783 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$31,783 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $4,680 Cost: $5,500 |
- | - | - | - | - | - | $4,680 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,680 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $83,594 Cost: $37,572 |
$23,553 | 419,109 | $3,527 | 788 | $14,389 | 2,359 | $42,125 | - | $23,553 419,109 kWh |
$3,527 788 kW-months/year |
$14,389 2,359 MMBtu |
$42,125 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $55,356 Cost: $6,700 |
$15,688 | 276,085 | $2,223 | 497 | - | - | $37,445 | - | $15,688 276,085 kWh |
$2,223 497 kW-months/year |
- - MMBtu |
$37,445 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |