Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2000 |
Principal Product | Automotive Parts |
NAICS | n/a |
SIC | 3231 - Products Of Purchased Glass |
Sales | $50,000,000-$100,000,000 |
# of Employees | 490 |
Plant Area (Sq.Ft.) | 280,000 |
Annual Production | 1,645,000 Units |
Production Hrs. Annual | 5,640 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,031,971 | 12,384,232 | kWh | $0.08 |
Electricity Demand | $2,106 | 25,268 | kW-months/year | $0.08 |
Natural Gas | $51,838 | 21,674 | MMBtu | $2.39 |
TOTAL ENERGY COSTS | $1,085,915 | |||
RECOMMENDED SAVINGS* | $67,505 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $66,876 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,393 Cost: - |
$6,393 | 189,039 | - | - | - | - | - | - | - | - |
$6,393 189,039 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,494 Cost: - |
$14,592 | 347,304 | $902 | 62 | - | - | - | - | - | - |
$14,592 347,304 kWh |
$902 62 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $629 Cost: - |
$627 | 14,654 | $2 | 2 | - | - | - | - | - | - |
$627 14,654 kWh |
$2 2 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $24,816 Cost: - |
- | - | - | - | $24,816 | 56,400 | - | - | - | - |
- - kWh |
- - kW-months/year |
$24,816 56,400 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,493 Cost: - |
- | - | - | - | - | - | - | - | $2,493 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$2,493 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $17,680 Cost: - |
- | - | - | - | - | - | $17,680 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$17,680 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $67,505 Cost: - |
$21,612 | 550,997 | $904 | 64 | $24,816 | 56,400 | $17,680 | - | $2,493 | - | $21,612 550,997 kWh |
$904 64 kW-months/year |
$24,816 56,400 Tgal |
$17,680 - $ |
$2,493 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $66,876 Cost: - |
$20,985 | 536,343 | $902 | 62 | $24,816 | 56,400 | $17,680 | - | $2,493 | - | $20,985 536,343 kWh |
$902 62 kW-months/year |
$24,816 56,400 Tgal |
$17,680 - $ |
$2,493 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes |