Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2000 |
Principal Product | Car Batteries |
NAICS | n/a |
SIC | 3691 - Storage Batteries |
Sales | $50,000,000-$100,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 195,000 |
Annual Production | 2,900,000 Pieces |
Production Hrs. Annual | 4,160 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,305,153 | 26,901,231 | kWh | $0.05 |
Electricity Demand | $85,055 | 52,884 | kW-months/year | $1.61 |
Electricity Fees | $449,439 | - | $ | - |
Natural Gas | $146,707 | 53,550 | MMBtu | $2.74 |
TOTAL ENERGY COSTS | $1,986,354 | |||
RECOMMENDED SAVINGS* | $2,294,730 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $39,257 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,575 Cost: $6,093 |
$6,008 | 122,509 | $567 | 1 | - | - | - | - | - | - | - | - |
$6,008 122,509 kWh |
$567 1 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $31,004 Cost: $50 |
- | - | - | - | - | - | - | - | - | - | $31,004 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
$31,004 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $16,950 Cost: $25,000 |
- | - | - | - | - | - | $16,950 | 6,186 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$16,950 6,186 MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $1,684,933 Cost: $2,200,000 |
$1,287,720 | 26,279,895 | $57,960 | 36,000 | - | - | $285,253 | (-104,107) | - | - | $54,000 | - |
$1,287,720 26,279,895 kWh |
$57,960 36,000 kW-months/year |
- - $ |
$285,253 (-104,107) MMBtu |
- - lb |
$54,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,678 Cost: $4,886 |
$1,603 | 32,825 | $75 | 4 | - | - | - | - | - | - | - | - |
$1,603 32,825 kWh |
$75 4 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $93,870 Cost: $9,000 |
- | - | - | - | - | - | - | - | $93,870 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$93,870 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5218 REUSE / RECYCLE/ SELL RUBBER PRODUCTS |
Savings: $2,400 Cost: - |
- | - | - | - | - | - | - | - | $2,400 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$2,400 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $7,881 Cost: $9,000 |
- | - | - | - | - | - | - | - | - | - | $7,881 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
$7,881 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.651 INSTALL BACK-UP EQUIPMENT |
Savings: $449,439 Cost: $2,100,000 |
- | - | - | - | $449,439 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$449,439 - $ |
- - MMBtu |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $2,294,730 Cost: $4,354,029 |
$1,295,331 | 26,435,229 | $58,602 | 36,005 | $449,439 | - | $302,203 | (-97,921) | $96,270 | - | $92,885 | - | $1,295,331 26,435,229 kWh |
$58,602 36,005 kW-months/year |
$449,439 - $ |
$302,203 (-97,921) MMBtu |
$96,270 - lb |
$92,885 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $39,257 Cost: $11,029 |
$7,611 | 155,334 | $642 | 5 | - | - | - | - | - | - | $31,004 | - | $7,611 155,334 kWh |
$642 5 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
$31,004 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Administrative Changes |