Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2000 |
Principal Product | Quilting Machines |
NAICS | n/a |
SIC | 3552 - Textile Machinery |
Sales | $10,000,000-$50,000,000 |
# of Employees | 205 |
Plant Area (Sq.Ft.) | 65,000 |
Annual Production | 600 Pieces |
Production Hrs. Annual | 2,730 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $103,463 | 1,448,417 | kWh | $0.07 |
Electricity Demand | $31,844 | 3,912 | kW-months/year | $8.14 |
TOTAL ENERGY COSTS | $135,307 | |||
RECOMMENDED SAVINGS* | $126,840 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $43,493 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,696 Cost: $10,710 |
$4,719 | 96,424 | $1,977 | 20 | - | - | - | - | - | - |
$4,719 96,424 kWh |
$1,977 20 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $17,512 Cost: $21,931 |
$9,081 | 185,229 | $8,756 | 79 | - | - | $(-325) | - | - | - |
$9,081 185,229 kWh |
$8,756 79 kW-months/year |
- - $ |
$(-325) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $6,321 Cost: $50 |
- | - | - | - | - | - | $6,321 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$6,321 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,910 Cost: $647 |
$972 | 19,930 | $938 | 10 | - | - | - | - | - | - |
$972 19,930 kWh |
$938 10 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $7,535 Cost: $9,667 |
$7,535 | 106,096 | - | - | - | - | - | - | - | - |
$7,535 106,096 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $511 Cost: - |
$511 | 7,327 | - | - | - | - | - | - | - | - |
$511 7,327 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $833 Cost: $590 |
$911 | 12,896 | - | - | - | - | $(-78) | - | - | - |
$911 12,896 kWh |
- - kW-months/year |
- - $ |
$(-78) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $5,994 Cost: $4,990 |
$5,994 | 84,408 | - | - | - | - | - | - | - | - |
$5,994 84,408 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $18,487 Cost: $13,000 |
$18,487 | 377,198 | - | - | - | - | - | - | - | - |
$18,487 377,198 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $2,000 Cost: - |
- | - | - | - | - | - | $2,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.515 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE |
Savings: $58,300 Cost: $87,900 |
- | - | - | - | $20,800 | - | - | - | $37,500 | - |
- - kWh |
- - kW-months/year |
$20,800 - $ |
- - $ |
$37,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $741 Cost: $520 |
$159 | 3,224 | $36 | 1 | - | - | $546 | - | - | - |
$159 3,224 kWh |
$36 1 kW-months/year |
- - $ |
$546 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $126,840 Cost: $150,005 |
$48,369 | 892,732 | $11,707 | 110 | $20,800 | - | $8,464 | - | $37,500 | - | $48,369 892,732 kWh |
$11,707 110 kW-months/year |
$20,800 - $ |
$8,464 - $ |
$37,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $43,493 Cost: $30,507 |
$31,753 | 601,407 | $2,951 | 31 | - | - | $8,789 | - | - | - | $31,753 601,407 kWh |
$2,951 31 kW-months/year |
- - $ |
$8,789 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product |