Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2000 |
Principal Product | Vinyl coated steel wire closet storage units |
NAICS | n/a |
SIC | 2542 - Partitions And Fixtures, Except Wood |
Sales | $100,000,000-$500,000,000 |
# of Employees | 800 |
Plant Area (Sq.Ft.) | 600,000 |
Annual Production | 100,000 Thousand Feet |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $782,188 | 16,596,425 | kWh | $0.05 |
Electricity Demand | $262,080 | 44,047 | kW-months/year | $5.95 |
TOTAL ENERGY COSTS | $1,044,268 | |||
RECOMMENDED SAVINGS* | $136,749 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $125,878 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,935 Cost: $2,079 |
$5,555 | 118,113 | $2,380 | 33 | - | - | - | - | - | - | - | - |
$5,555 118,113 kWh |
$2,380 33 kW-months/year |
- - Tgal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $945 Cost: $886 |
$247 | 5,275 | $43 | 1 | - | - | - | - | $655 | - | - | - |
$247 5,275 kWh |
$43 1 kW-months/year |
- - Tgal |
- - lb |
$655 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $6,067 Cost: $3,080 |
$6,067 | 128,957 | - | - | - | - | - | - | - | - | - | - |
$6,067 128,957 kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $35,535 Cost: $1,000 |
- | - | - | - | - | - | - | - | - | - | $35,535 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
$35,535 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7122 DISCONNECT BALLASTS |
Savings: $4,531 Cost: $22 |
$3,860 | 82,063 | $671 | 9 | - | - | - | - | - | - | - | - |
$3,860 82,063 kWh |
$671 9 kW-months/year |
- - Tgal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $51,429 Cost: $50 |
- | - | - | - | - | - | - | - | $51,429 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
$51,429 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $16,668 Cost: $60,448 |
$14,203 | 302,169 | $2,465 | 35 | - | - | - | - | - | - | - | - |
$14,203 302,169 kWh |
$2,465 35 kW-months/year |
- - Tgal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $2,515 Cost: - |
- | - | - | - | - | - | $2,515 | 15,600 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$2,515 15,600 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $5,640 Cost: $1,018 |
- | - | - | - | $5,640 | 17,952,000 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,640 17,952,000 Tgal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $700 Cost: $1,895 |
- | - | - | - | - | - | $700 | 2,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$700 2,000 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $4,784 Cost: - |
- | - | - | - | - | - | - | - | $4,784 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
$4,784 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $136,749 Cost: $70,478 |
$29,932 | 636,577 | $5,559 | 78 | $5,640 | 17,952,000 | $3,215 | 17,600 | $56,868 | - | $35,535 | - | $29,932 636,577 kWh |
$5,559 78 kW-months/year |
$5,640 17,952,000 Tgal |
$3,215 17,600 lb |
$56,868 - $ |
$35,535 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $125,878 Cost: $67,543 |
$26,072 | 554,514 | $4,888 | 69 | - | - | $2,515 | 15,600 | $56,868 | - | $35,535 | - | $26,072 554,514 kWh |
$4,888 69 kW-months/year |
- - Tgal |
$2,515 15,600 lb |
$56,868 - $ |
$35,535 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost |