Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2001 |
Principal Product | Mobile homes |
NAICS | n/a |
SIC | 2451 - Mobile Homes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 127,000 |
Annual Production | 500 Units |
Production Hrs. Annual | 2,313 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $55,794 | 993,259 | kWh | $0.06 |
Electricity Demand | $29,470 | 4,245 | kW-months/year | $6.94 |
TOTAL ENERGY COSTS | $85,264 | |||
RECOMMENDED SAVINGS* | $63,139 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,418 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $5,100 Cost: $50 |
- | - | - | - | - | - | $5,100 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,100 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,082 Cost: $5,941 |
$5,347 | 95,545 | $2,735 | 33 | - | - | - | - |
$5,347 95,545 kWh |
$2,735 33 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,081 Cost: $410 |
$1,123 | 13,189 | - | - | - | - | $(-42) | - |
$1,123 13,189 kWh |
- - kW-months/year |
- - MMBtu |
$(-42) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $1,037 Cost: - |
- | - | - | - | - | - | $1,037 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,037 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7145 INSTALL SKYLIGHTS |
Savings: $21,467 Cost: $60,291 |
$12,656 | 225,967 | $9,411 | 113 | - | - | $(-600) | - |
$12,656 225,967 kWh |
$9,411 113 kW-months/year |
- - MMBtu |
$(-600) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6242 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION |
Savings: $5,591 Cost: - |
- | - | $5,591 | 67 | - | - | - | - |
- - kWh |
$5,591 67 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $800 Cost: - |
- | - | - | - | - | - | $800 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $5,400 Cost: - |
- | - | - | - | - | - | $5,400 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.444 INSTALL SYSTEM TO COLLECT SCRAP |
Savings: $14,581 Cost: $4,926 |
- | - | - | - | $(-419) | 18 | $15,000 | - |
- - kWh |
- - kW-months/year |
$(-419) 18 MMBtu |
$15,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $63,139 Cost: $71,618 |
$19,126 | 334,701 | $17,737 | 213 | $(-419) | 18 | $26,695 | - | $19,126 334,701 kWh |
$17,737 213 kW-months/year |
$(-419) 18 MMBtu |
$26,695 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,418 Cost: $460 |
$1,123 | 13,189 | - | - | - | - | $12,295 | - | $1,123 13,189 kWh |
- - kW-months/year |
- - MMBtu |
$12,295 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes |