Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2001 |
Principal Product | Acoustical Ceiling Tiles |
NAICS | n/a |
SIC | 3296 - Mineral Wool |
Sales | $100,000,000-$500,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 1,132,560 |
Annual Production | 150,000 Thousand Feet |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $914,469 | 37,784,975 | kWh | $0.02 |
Electricity Demand | $658,925 | 71,520 | kW-months/year | $9.21 |
Natural Gas | $2,818,245 | 667,601 | MMBtu | $4.22 |
TOTAL ENERGY COSTS | $4,392,321 | |||
RECOMMENDED SAVINGS* | $648,788 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $248,075 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $46,074 Cost: $2,910 |
$21,543 | 797,888 | $23,904 | 274 | - | - | - | - | $627 | - |
$21,543 797,888 kWh |
$23,904 274 kW-months/year |
- - MMBtu |
- - lb |
$627 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $190,612 Cost: $67,472 |
$148,650 | 5,505,539 | $41,962 | 481 | - | - | - | - | - | - |
$148,650 5,505,539 kWh |
$41,962 481 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $703 Cost: $621 |
$703 | 15,614 | - | - | - | - | - | - | - | - |
$703 15,614 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $56,760 Cost: $143,877 |
$41,493 | 1,536,765 | $15,267 | 175 | - | - | - | - | - | - |
$41,493 1,536,765 kWh |
$15,267 175 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $19,545 Cost: $36,000 |
- | - | - | - | - | - | - | - | $19,545 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$19,545 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $26,575 Cost: $46,800 |
$22,055 | 816,870 | $4,520 | 52 | - | - | - | - | - | - |
$22,055 816,870 kWh |
$4,520 52 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7212 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS |
Savings: $191,133 Cost: $282,000 |
- | - | - | - | $191,133 | 45,292 | - | - | - | - |
- - kWh |
- - kW-months/year |
$191,133 45,292 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $5,102 Cost: $20,000 |
$5,102 | 188,963 | - | - | - | - | - | - | - | - |
$5,102 188,963 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $682 Cost: $1,895 |
- | - | - | - | - | - | $682 | 397 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$682 397 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $111,602 Cost: $1,600 |
$81,504 | 3,018,656 | $30,098 | 345 | - | - | - | - | - | - |
$81,504 3,018,656 kWh |
$30,098 345 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $648,788 Cost: $603,175 |
$321,050 | 11,880,295 | $115,751 | 1,327 | $191,133 | 45,292 | $682 | 397 | $20,172 | - | $321,050 11,880,295 kWh |
$115,751 1,327 kW-months/year |
$191,133 45,292 MMBtu |
$682 397 lb |
$20,172 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $248,075 Cost: $211,970 |
$190,846 | 7,057,918 | $57,229 | 656 | - | - | - | - | - | - | $190,846 7,057,918 kWh |
$57,229 656 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Administrative Changes |