Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2002 |
Principal Product | Grapefruit Concentrate |
NAICS | n/a |
SIC | 2033 - Canned Fruits And Vegetables |
Sales | $100,000,000-$500,000,000 |
# of Employees | 140 |
Plant Area (Sq.Ft.) | 100,341 |
Annual Production | 3,400,000 Thousand Gallons |
Production Hrs. Annual | 5,248 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $654,635 | 10,238,618 | kWh | $0.06 |
Electricity Demand | $193,588 | 22,530 | kW-months/year | $8.59 |
TOTAL ENERGY COSTS | $848,223 | |||
RECOMMENDED SAVINGS* | $348,646 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $144,422 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,988 Cost: $5,732 |
$3,089 | 48,264 | $899 | 9 | - | - | - | - | - | - | - | - |
$3,089 48,264 kWh |
$899 9 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $5,901 Cost: $1,000 |
$5,901 | 71,092 | - | - | - | - | - | - | - | - | - | - |
$5,901 71,092 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $13,442 Cost: $36,067 |
$7,555 | 118,054 | $6,191 | 60 | - | - | $(-304) | - | - | - | - | - |
$7,555 118,054 kWh |
$6,191 60 kW-months/year |
- - MMBtu |
$(-304) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $65,908 Cost: $37,050 |
$65,908 | 794,074 | - | - | - | - | - | - | - | - | - | - |
$65,908 794,074 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,494 Cost: - |
$3,494 | 42,099 | - | - | - | - | - | - | - | - | - | - |
$3,494 42,099 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $45,724 Cost: $81,293 |
$32,324 | 505,056 | $13,400 | 130 | - | - | - | - | - | - | - | - |
$32,324 505,056 kWh |
$13,400 130 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $27,545 Cost: $120,962 |
- | - | - | - | $27,791 | 25,264 | $(-246) | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$27,791 25,264 MMBtu |
$(-246) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $20,543 Cost: - |
$15,719 | 245,604 | $4,824 | 47 | - | - | - | - | - | - | - | - |
$15,719 245,604 kWh |
$4,824 47 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $3,134 Cost: - |
$2,101 | 32,826 | $1,033 | 10 | - | - | - | - | - | - | - | - |
$2,101 32,826 kWh |
$1,033 10 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $30,592 Cost: $15,000 |
- | - | - | - | - | - | - | - | $30,592 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$30,592 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5318 RECYCLE FLUORESCENT LAMPS |
Savings: $63 Cost: - |
- | - | - | - | - | - | - | - | $63 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$63 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $126,744 Cost: $400,000 |
- | - | - | - | - | - | - | - | - | - | $126,744 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$126,744 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $1,568 Cost: $1,487 |
- | - | - | - | - | - | - | - | $1,568 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$1,568 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $348,646 Cost: $698,591 |
$136,091 | 1,857,069 | $26,347 | 256 | $27,791 | 25,264 | $(-550) | - | $32,223 | - | $126,744 | - | $136,091 1,857,069 kWh |
$26,347 256 kW-months/year |
$27,791 25,264 MMBtu |
$(-550) - $ |
$32,223 - $ |
$126,744 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $144,422 Cost: $125,562 |
$122,635 | 1,667,923 | $20,156 | 196 | - | - | - | - | $1,631 | - | - | - | $122,635 1,667,923 kWh |
$20,156 196 kW-months/year |
- - MMBtu |
- - $ |
$1,631 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | Primary Product |