Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2002
Principal Product Electronic Control & Monitoring Systems
NAICS n/a
SIC 3812 - Search And Navigation Equipment
Sales n/a
# of Employees 420
Plant Area (Sq.Ft.) 165,000
Annual Production 0 Pieces
Production Hrs. Annual 5,304
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $307,854 8,101,410 kWh $0.04
Electricity Demand $126,870 25,476 kW-months/year $4.98
TOTAL ENERGY COSTS $434,724
RECOMMENDED SAVINGS* $185,692 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $53,122
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Administrative Changes One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$26,416
Cost:
$12,233
$26,416 480,296 - - - - - - $26,416
480,296
kWh
-
-
kW-months/year
-
-
$
-
-
$
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$5,458
Cost:
$8,116
$3,665 96,451 $1,793 30 - - - - $3,665
96,451
kWh
$1,793
30
kW-months/year
-
-
$
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$26,706
Cost:
$107,644
$20,550 540,800 $6,156 103 - - - - $20,550
540,800
kWh
$6,156
103
kW-months/year
-
-
$
-
-
$
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$36,062
Cost:
$107,250
$36,062 655,667 - - - - - - $36,062
655,667
kWh
-
-
kW-months/year
-
-
$
-
-
$
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,754
Cost:
$2,000
$1,754 31,892 - - - - - - $1,754
31,892
kWh
-
-
kW-months/year
-
-
$
-
-
$
06: 2.6225 ELIMINATE THIRD SHIFT Savings:
$11,540
Cost:
-
$11,540 209,813 - - - - - - $11,540
209,813
kWh
-
-
kW-months/year
-
-
$
-
-
$
07: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$39,511
Cost:
$50
- - - - - - $39,511 - -
-
kWh
-
-
kW-months/year
-
-
$
$39,511
-
$
08: 3.5318 RECYCLE FLUORESCENT LAMPS Savings:
$1,147
Cost:
$1,895
- - - - $1,147 - - - -
-
kWh
-
-
kW-months/year
$1,147
-
$
-
-
$
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$37,098
Cost:
$15,000
- - - - $37,098 - - - -
-
kWh
-
-
kW-months/year
$37,098
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$185,692
Cost:
$254,188
$99,987 2,014,919 $7,949 133 $38,245 - $39,511 - $99,987
2,014,919
kWh
$7,949
133
kW-months/year
$38,245
-
$
$39,511
-
$
TOTAL IMPLEMENTED Savings:
$53,122
Cost:
$119,877
$46,966 1,021,096 $6,156 103 - - - - $46,966
1,021,096
kWh
$6,156
103
kW-months/year
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Administrative Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Administrative Changes One-time Revenue or Avoided Cost