Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2002 |
Principal Product | Electronic Control & Monitoring Systems |
NAICS | n/a |
SIC | 3812 - Search And Navigation Equipment |
Sales | n/a |
# of Employees | 420 |
Plant Area (Sq.Ft.) | 165,000 |
Annual Production | 0 Pieces |
Production Hrs. Annual | 5,304 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $307,854 | 8,101,410 | kWh | $0.04 |
Electricity Demand | $126,870 | 25,476 | kW-months/year | $4.98 |
TOTAL ENERGY COSTS | $434,724 | |||
RECOMMENDED SAVINGS* | $185,692 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $53,122 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $26,416 Cost: $12,233 |
$26,416 | 480,296 | - | - | - | - | - | - |
$26,416 480,296 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $5,458 Cost: $8,116 |
$3,665 | 96,451 | $1,793 | 30 | - | - | - | - |
$3,665 96,451 kWh |
$1,793 30 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $26,706 Cost: $107,644 |
$20,550 | 540,800 | $6,156 | 103 | - | - | - | - |
$20,550 540,800 kWh |
$6,156 103 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $36,062 Cost: $107,250 |
$36,062 | 655,667 | - | - | - | - | - | - |
$36,062 655,667 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,754 Cost: $2,000 |
$1,754 | 31,892 | - | - | - | - | - | - |
$1,754 31,892 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6225 ELIMINATE THIRD SHIFT |
Savings: $11,540 Cost: - |
$11,540 | 209,813 | - | - | - | - | - | - |
$11,540 209,813 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $39,511 Cost: $50 |
- | - | - | - | - | - | $39,511 | - |
- - kWh |
- - kW-months/year |
- - $ |
$39,511 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5318 RECYCLE FLUORESCENT LAMPS |
Savings: $1,147 Cost: $1,895 |
- | - | - | - | $1,147 | - | - | - |
- - kWh |
- - kW-months/year |
$1,147 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $37,098 Cost: $15,000 |
- | - | - | - | $37,098 | - | - | - |
- - kWh |
- - kW-months/year |
$37,098 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $185,692 Cost: $254,188 |
$99,987 | 2,014,919 | $7,949 | 133 | $38,245 | - | $39,511 | - | $99,987 2,014,919 kWh |
$7,949 133 kW-months/year |
$38,245 - $ |
$39,511 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $53,122 Cost: $119,877 |
$46,966 | 1,021,096 | $6,156 | 103 | - | - | - | - | $46,966 1,021,096 kWh |
$6,156 103 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | One-time Revenue or Avoided Cost |