Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2003 |
Principal Product | Roof shingles |
NAICS | 324122 - Asphalt Shingle and Coating Materials Manufacturing |
SIC | 2952 - Asphalt Felts And Coatings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 115 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 3,200,000 Pieces |
Production Hrs. Annual | 7,800 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $379,031 | 8,064,988 | kWh | $0.05 |
Electricity Demand | $23,085 | 15,516 | kW-months/year | $1.49 |
Natural Gas | $423,782 | 103,677 | MMBtu | $4.09 |
TOTAL ENERGY COSTS | $1,182,173 | |||
RECOMMENDED SAVINGS* | $506,135 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $81,290 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,514 Cost: $1,631 |
$12,014 | 235,562 | $500 | 28 | - | - | - | - | - | - | - | - | - | - |
$12,014 235,562 kWh |
$500 28 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,785 Cost: $1,826 |
$1,713 | 33,580 | $72 | 4 | - | - | - | - | - | - | - | - | - | - |
$1,713 33,580 kWh |
$72 4 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $58,093 Cost: $31,024 |
- | - | - | - | $58,093 | 14,204 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$58,093 14,204 MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $13,902 Cost: $27,000 |
- | - | - | - | - | - | - | - | - | - | $13,902 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$13,902 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $7,223 Cost: $973 |
- | - | - | - | $7,223 | 1,766 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,223 1,766 MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2424 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS |
Savings: $19,080 Cost: $34,976 |
- | - | - | - | $19,080 | 4,665 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,080 4,665 MMBtu |
- - lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $333,770 Cost: $250,000 |
$(-18,857) | (-369,750) | $(-3,648) | (-204) | - | - | $356,275 | 29,000,000 | - | - | - | - | - | - |
$(-18,857) (-369,750) kWh |
$(-3,648) (-204) kW-months/year |
- - MMBtu |
$356,275 29,000,000 lb |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.651 INSTALL BACK-UP EQUIPMENT |
Savings: $57,960 Cost: $109,500 |
- | - | - | - | - | - | - | - | - | - | - | - | $57,960 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
$57,960 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.444 INSTALL SYSTEM TO COLLECT SCRAP |
Savings: $1,808 Cost: $700 |
- | - | - | - | - | - | - | - | $1,808 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$1,808 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $506,135 Cost: $457,630 |
$(-5,130) | (-100,608) | $(-3,076) | (-172) | $84,396 | 20,635 | $356,275 | 29,000,000 | $1,808 | - | $13,902 | - | $57,960 | - | $(-5,130) (-100,608) kWh |
$(-3,076) (-172) kW-months/year |
$84,396 20,635 MMBtu |
$356,275 29,000,000 lb |
$1,808 - $ |
$13,902 - $ |
$57,960 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $81,290 Cost: $114,630 |
$13,727 | 269,142 | $572 | 32 | $7,223 | 1,766 | - | - | $1,808 | - | - | - | $57,960 | - | $13,727 269,142 kWh |
$572 32 kW-months/year |
$7,223 1,766 MMBtu |
- - lb |
$1,808 - $ |
- - $ |
$57,960 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Increase in Production |