Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2003 |
Principal Product | Fragrances |
NAICS | 311999 - All Other Miscellaneous Food Manufacturing |
SIC | 2087 - Flavoring Extracts And Syrups, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 179 |
Plant Area (Sq.Ft.) | 73,000 |
Annual Production | 100,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $116,106 | 3,379,839 | kWh | $0.03 |
Electricity Demand | $34,805 | 861 | kW-months/year | $40.42 |
Natural Gas | $29,609 | 5,027 | MMBtu | $5.89 |
TOTAL ENERGY COSTS | $556,460 | |||
RECOMMENDED SAVINGS* | $691,460 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $94,985 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,414 Cost: $8,936 |
$7,913 | 232,735 | $2,501 | 28 | - | - | - | - | - | - |
$7,913 232,735 kWh |
$2,501 28 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $4,569 Cost: $2,000 |
$4,569 | 99,331 | - | - | - | - | - | - | - | - |
$4,569 99,331 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $51,357 Cost: $165,670 |
$37,701 | 1,108,858 | $13,656 | 621 | - | - | - | - | - | - |
$37,701 1,108,858 kWh |
$13,656 621 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $84,571 Cost: $191,945 |
$65,923 | 1,938,915 | $18,648 | 212 | - | - | - | - | - | - |
$65,923 1,938,915 kWh |
$18,648 212 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $29,609 Cost: $3,005 |
- | - | - | - | $29,609 | 5,027 | - | - | - | - |
- - kWh |
- - kW-months/year |
$29,609 5,027 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $375,940 Cost: $302,000 |
- | - | - | - | - | - | $375,940 | 95,659,200 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$375,940 95,659,200 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $135,000 Cost: $32,000 |
- | - | - | - | - | - | - | - | $135,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$135,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $691,460 Cost: $705,556 |
$116,106 | 3,379,839 | $34,805 | 861 | $29,609 | 5,027 | $375,940 | 95,659,200 | $135,000 | - | $116,106 3,379,839 kWh |
$34,805 861 kW-months/year |
$29,609 5,027 MMBtu |
$375,940 95,659,200 Tgal |
$135,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $94,985 Cost: $200,881 |
$73,836 | 2,171,650 | $21,149 | 240 | - | - | - | - | - | - | $73,836 2,171,650 kWh |
$21,149 240 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes |