IAC logo
IAC Assessment: UF0338
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0338
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2004
Principal Product Drills and Drill Rigs
NAICS 333131 - Mining Machinery and Equipment Manufacturing
SIC 3532 - Mining Machinery
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 1,750,000
Annual Production 45 Pieces
Production Hrs. Annual 2,210
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $129,680 2,146,700 kWh $0.06
Electricity Demand $38,859 6,531 kW-months/year $5.95
Electricity Fees $13,190 - $ -
TOTAL ENERGY COSTS $184,532
RECOMMENDED SAVINGS* $49,127 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,833
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Disposal Electricity Usage Electricity Demand Water Disposal
$ kWh $ kW-months/year $ Tgal
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,833
Cost:
$376
$4,833 57,080 - - - - $4,833
57,080
kWh
-
-
kW-months/year
-
-
Tgal
02: 3.7141 IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM Savings:
$17,356
Cost:
$246
$17,356 267,017 - - - - $17,356
267,017
kWh
-
-
kW-months/year
-
-
Tgal
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,636
Cost:
$15,747
$5,855 90,348 $2,781 36 - - $5,855
90,348
kWh
$2,781
36
kW-months/year
-
-
Tgal
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$7,517
Cost:
$20,000
$5,626 86,549 $1,891 25 - - $5,626
86,549
kWh
$1,891
25
kW-months/year
-
-
Tgal
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,081
Cost:
-
$1,081 11,068 - - - - $1,081
11,068
kWh
-
-
kW-months/year
-
-
Tgal
06: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS Savings:
$6,607
Cost:
$200
$4,310 66,300 $2,297 30 - - $4,310
66,300
kWh
$2,297
30
kW-months/year
-
-
Tgal
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,694
Cost:
$7,494
$1,105 16,999 $589 8 - - $1,105
16,999
kWh
$589
8
kW-months/year
-
-
Tgal
08: 3.4155 METER WASTE WATER Savings:
$1,403
Cost:
$1,500
- - - - $1,403 370 -
-
kWh
-
-
kW-months/year
$1,403
370
Tgal
TOTAL RECOMMENDED Savings:
$49,127
Cost:
$45,563
$40,166 595,361 $7,558 99 $1,403 370 $40,166
595,361
kWh
$7,558
99
kW-months/year
$1,403
370
Tgal
TOTAL IMPLEMENTED Savings:
$4,833
Cost:
$376
$4,833 57,080 - - - - $4,833
57,080
kWh
-
-
kW-months/year
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ Tgal
Electricity Usage Electricity Demand Water Disposal Electricity Usage Electricity Demand Water Disposal