Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2004
Principal Product Electrical Connectors
NAICS 335931 - Current-Carrying Wiring Device Manufacturing
SIC 3643 - Current-carrying Wiring Devices
Sales n/a
# of Employees 225
Plant Area (Sq.Ft.) 278,000
Annual Production 0 Pieces
Production Hrs. Annual 6,240
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $373,004 4,399,823 kWh $0.08
Electricity Demand $123,916 16,615 kW-months/year $7.46
Natural Gas $14,680 11,162 MMBtu $1.32
TOTAL ENERGY COSTS $511,600
RECOMMENDED SAVINGS* $105,588 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Disposal Primary Product Electricity Usage Electricity Demand Water Disposal Primary Product
$ kWh $ kW-months/year $ Tgal $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$12,849
Cost:
$2,250
$12,849 225,416 - - - - - - $12,849
225,416
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$13,502
Cost:
$15,442
$9,295 163,070 $4,207 47 - - - - $9,295
163,070
kWh
$4,207
47
kW-months/year
-
-
Tgal
-
-
$
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$3,562
Cost:
-
$2,029 35,601 $1,533 17 - - - - $2,029
35,601
kWh
$1,533
17
kW-months/year
-
-
Tgal
-
-
$
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,546
Cost:
$1,000
$1,546 27,116 - - - - - - $1,546
27,116
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,832
Cost:
-
$1,832 32,135 - - - - - - $1,832
32,135
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$813
Cost:
$1,400
$689 12,089 $124 1 - - - - $689
12,089
kWh
$124
1
kW-months/year
-
-
Tgal
-
-
$
07: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$6,509
Cost:
$2,200
$1,496 26,252 $5,013 56 - - - - $1,496
26,252
kWh
$5,013
56
kW-months/year
-
-
Tgal
-
-
$
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,009
Cost:
-
$1,009 17,700 - - - - - - $1,009
17,700
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,302
Cost:
$1,278
$854 14,977 $448 5 - - - - $854
14,977
kWh
$448
5
kW-months/year
-
-
Tgal
-
-
$
10: 4.4240 IMPROVE SPACE COMFORT CONDITIONING Savings:
$40,000
Cost:
$5,000
- - - - - - $40,000 - -
-
kWh
-
-
kW-months/year
-
-
Tgal
$40,000
-
$
11: 4.3110 SCHEDULE DELIVERIES ACCORDING TO DEMAND Savings:
$21,450
Cost:
-
- - - - - - $21,450 - -
-
kWh
-
-
kW-months/year
-
-
Tgal
$21,450
-
$
12: 3.5318 RECYCLE FLUORESCENT LAMPS Savings:
$1,214
Cost:
$3,496
- - - - $1,214 - - - -
-
kWh
-
-
kW-months/year
$1,214
-
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$105,588
Cost:
$32,066
$31,599 554,356 $11,325 126 $1,214 - $61,450 - $31,599
554,356
kWh
$11,325
126
kW-months/year
$1,214
-
Tgal
$61,450
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ Tgal $ $
Electricity Usage Electricity Demand Water Disposal Primary Product Electricity Usage Electricity Demand Water Disposal Primary Product