IAC Center | University of Florida |
---|---|
Assessment Year | 2005 |
Principal Product | Military Aircrafts |
NAICS | 336411 - Aircraft Manufacturing |
SIC | 3721 - Aircraft |
Sales | $10,000,000-$50,000,000 |
# of Employees | 277 |
Plant Area (Sq.Ft.) | 192,534 |
Annual Production | 1 Units |
Production Hrs. Annual | 3,952 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $179,171 | 3,279,329 | kWh | $0.05 |
Electricity Demand | $58,225 | 7,669 | kW-months/year | $7.59 |
LPG | $125,092 | 4,355 | MMBtu | $28.72 |
TOTAL ENERGY COSTS | $362,488 | |||
RECOMMENDED SAVINGS* | $317,500 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $246,094 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Increase in Production | Electricity Usage | Electricity Demand | LPG | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE |
Savings: $6,120 Cost: $978 |
- | - | - | - | $6,120 | 366 | - | - |
- - kWh |
- - kW-months/year |
$6,120 366 MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,368 Cost: $650 |
$2,368 | 41,541 | - | - | - | - | - | - |
$2,368 41,541 kWh |
- - kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $6,271 Cost: $1,680 |
$3,920 | 103,168 | $2,351 | 25 | - | - | - | - |
$3,920 103,168 kWh |
$2,351 25 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,453 Cost: $675 |
$1,533 | 40,335 | $920 | 10 | - | - | - | - |
$1,533 40,335 kWh |
$920 10 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,952 Cost: $4,688 |
$2,952 | 77,685 | - | - | - | - | - | - |
$2,952 77,685 kWh |
- - kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $7,254 Cost: $20,000 |
$3,631 | 95,550 | $3,623 | 38 | - | - | - | - |
$3,631 95,550 kWh |
$3,623 38 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $18,424 Cost: - |
$18,424 | 484,831 | - | - | - | - | - | - |
$18,424 484,831 kWh |
- - kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $3,385 Cost: - |
$3,385 | 89,076 | - | - | - | - | - | - |
$3,385 89,076 kWh |
- - kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE |
Savings: $5,477 Cost: $800 |
- | - | - | - | $5,477 | 328 | - | - |
- - kWh |
- - kW-months/year |
$5,477 328 MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.5194 REDESIGN PROCESS |
Savings: $61,200 Cost: $1,000,000 |
- | - | - | - | $61,200 | 3,661 | - | - |
- - kWh |
- - kW-months/year |
$61,200 3,661 MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.4240 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $1,596 Cost: $26,800 |
$911 | 23,970 | $685 | 7 | - | - | - | - |
$911 23,970 kWh |
$685 7 kW-months/year |
- - MMBtu |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.5140 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $100,000 Cost: $25,000 |
- | - | - | - | - | - | $100,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$100,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 4.4240 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $100,000 Cost: $50,000 |
- | - | - | - | - | - | $100,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$100,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $317,500 Cost: $1,131,271 |
$37,124 | 956,156 | $7,579 | 80 | $72,797 | 4,355 | $200,000 | - | $37,124 956,156 kWh |
$7,579 80 kW-months/year |
$72,797 4,355 MMBtu |
$200,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $246,094 Cost: $106,583 |
$30,541 | 782,921 | $3,956 | 42 | $11,597 | 694 | $200,000 | - | $30,541 782,921 kWh |
$3,956 42 kW-months/year |
$11,597 694 MMBtu |
$200,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Increase in Production | Electricity Usage | Electricity Demand | LPG | Increase in Production |