Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2007 |
Principal Product | Bottle Water |
NAICS | 312112 - Bottled Water Manufacturing |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 310,000 |
Annual Production | 60,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,887,557 | 24,650,102 | kWh | $0.08 |
Electricity Demand | $288,696 | 2,814 | kW-months/year | $102.59 |
TOTAL ENERGY COSTS | $2,182,253 | |||
RECOMMENDED SAVINGS* | $358,882 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $351,196 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,451 Cost: $4,491 |
$8,237 | 107,538 | $1,214 | 144 | - | - | - | - |
$8,237 107,538 kWh |
$1,214 144 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,897 Cost: $345 |
$3,897 | 50,785 | - | - | - | - | - | - |
$3,897 50,785 kWh |
- - kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,587 Cost: $50 |
$2,292 | 29,927 | $295 | 35 | - | - | - | - |
$2,292 29,927 kWh |
$295 35 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $1,469 Cost: $133 |
$1,275 | 16,644 | $194 | 23 | - | - | - | - |
$1,275 16,644 kWh |
$194 23 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $2,409 Cost: $30 |
$2,409 | 31,450 | - | - | - | - | - | - |
$2,409 31,450 kWh |
- - kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7145 INSTALL SKYLIGHTS |
Savings: $19,110 Cost: $35,054 |
$12,450 | 162,526 | $6,660 | 790 | - | - | - | - |
$12,450 162,526 kWh |
$6,660 790 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $3,509 Cost: $9,776 |
$3,509 | 45,804 | - | - | - | - | - | - |
$3,509 45,804 kWh |
- - kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $200 Cost: - |
$49 | 634 | - | - | $151 | - | - | - |
$49 634 kWh |
- - kW-months/year |
$151 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,508 Cost: $752 |
$2,508 | 28,407 | - | - | - | - | - | - |
$2,508 28,407 kWh |
- - kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.5121 REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH |
Savings: $77,607 Cost: $31,201 |
$70,477 | 826,008 | - | - | - | - | $7,130 | - |
$70,477 826,008 kWh |
- - kW-months/year |
- - $ |
$7,130 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,271 Cost: - |
$2,210 | 25,028 | - | - | $36 | - | $25 | - |
$2,210 25,028 kWh |
- - kW-months/year |
$36 - $ |
$25 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $53,219 Cost: $20,339 |
$46,249 | 603,772 | $6,970 | 827 | - | - | - | - |
$46,249 603,772 kWh |
$6,970 827 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $180,645 Cost: $263,004 |
$151,393 | 1,976,411 | $29,252 | 3,470 | - | - | - | - |
$151,393 1,976,411 kWh |
$29,252 3,470 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $358,882 Cost: $365,175 |
$306,955 | 3,904,934 | $44,585 | 5,289 | $187 | - | $7,155 | - | $306,955 3,904,934 kWh |
$44,585 5,289 kW-months/year |
$187 - $ |
$7,155 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $351,196 Cost: $354,514 |
$299,614 | 3,813,445 | $44,391 | 5,266 | $36 | - | $7,155 | - | $299,614 3,813,445 kWh |
$44,391 5,266 kW-months/year |
$36 - $ |
$7,155 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Ancillary Material Cost | Increase in Production |