IAC logo
IAC Assessment: UF0410
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2008
Principal Product Power Transformers
NAICS 335311 - Power, Distribution, and Specialty Transformer Manufacturing
SIC 3612 - Transformers, Except Electronic
Sales $10,000,000-$50,000,000
# of Employees 140
Plant Area (Sq.Ft.) 296,248
Annual Production 40 Pieces
Production Hrs. Annual 8,112
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $730,222 9,895,120 kWh $0.07
Electricity Demand $244,992 56,632 kW-months/year $4.33
Electricity Fees $25,920 - $ -
Natural Gas $105,340 7,923 MMBtu $13.30
TOTAL ENERGY COSTS $1,106,474
RECOMMENDED SAVINGS* $179,726 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,388
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$23,868
Cost:
$27,216
$21,722 293,558 $2,146 41 - - - - $21,722
293,558
kWh
$2,146
41
kW-months/year
-
-
MMBtu
-
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,023
Cost:
$19,505
$6,023 60,840 - - - - - - $6,023
60,840
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$1,665
Cost:
$459
$1,665 22,507 - - - - - - $1,665
22,507
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$3,229
Cost:
$233
- - - - $3,229 243 - - -
-
kWh
-
-
kW-months/year
$3,229
243
MMBtu
-
-
$
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,494
Cost:
-
$2,494 33,702 - - - - - - $2,494
33,702
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$4,311
Cost:
$122
$4,311 58,260 - - - - - - $4,311
58,260
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$136,962
Cost:
$129,516
$126,050 1,703,526 $10,912 210 - - - - $126,050
1,703,526
kWh
$10,912
210
kW-months/year
-
-
MMBtu
-
-
$
08: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$1,174
Cost:
$2,995
- - - - - - $1,174 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$1,174
-
$
TOTAL RECOMMENDED Savings:
$179,726
Cost:
$180,046
$162,265 2,172,393 $13,058 251 $3,229 243 $1,174 - $162,265
2,172,393
kWh
$13,058
251
kW-months/year
$3,229
243
MMBtu
$1,174
-
$
TOTAL IMPLEMENTED Savings:
$7,388
Cost:
$692
$4,159 56,209 - - $3,229 243 - - $4,159
56,209
kWh
-
-
kW-months/year
$3,229
243
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes