Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2009 |
Principal Product | Skidded Equipment, Precision Cleaning |
NAICS | 334513 - Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
SIC | 3823 - Process Control Instruments |
Sales | $5,000,000-$10,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 293,159 |
Annual Production | 7,000,000 Units |
Production Hrs. Annual | 2,080 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $66,888 | 788,562 | kWh | $0.08 |
Electricity Demand | $23,220 | 3,015 | kW-months/year | $7.70 |
Electricity Fees | $8,225 | - | $ | - |
LPG | $5,309 | 163 | MMBtu | $32.57 |
TOTAL ENERGY COSTS | $103,642 | |||
RECOMMENDED SAVINGS* | $17,402 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,885 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $587 Cost: - |
$587 | 6,909 | - | - | - | - | - | - |
$587 6,909 kWh |
- - kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $519 Cost: $837 |
$519 | 3,102 | - | - | - | - | - | - |
$519 3,102 kWh |
- - kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $585 Cost: $2,079 |
$585 | 6,880 | - | - | - | - | - | - |
$585 6,880 kWh |
- - kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,625 Cost: - |
$1,135 | 13,386 | $490 | 5 | - | - | - | - |
$1,135 13,386 kWh |
$490 5 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,507 Cost: $532 |
$3,507 | 30,761 | - | - | - | - | - | - |
$3,507 30,761 kWh |
- - kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $1,117 Cost: $981 |
$1,117 | 13,139 | - | - | - | - | - | - |
$1,117 13,139 kWh |
- - kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $677 Cost: $800 |
$677 | 7,966 | - | - | - | - | - | - |
$677 7,966 kWh |
- - kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.323 |
Savings: $2,066 Cost: - |
- | - | $2,066 | 22 | - | - | - | - |
- - kWh |
$2,066 22 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $477 Cost: - |
- | - | - | - | - | - | $477 | - |
- - kWh |
- - kW-months/year |
- - gal |
$477 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,802 Cost: - |
$1,509 | 17,749 | $1,293 | 14 | - | - | - | - |
$1,509 17,749 kWh |
$1,293 14 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.8143 RECYCLE CLEANING SOLVENT AND REUSE |
Savings: $3,440 Cost: $20,000 |
- | - | - | - | $3,440 | 3,440 | - | - |
- - kWh |
- - kW-months/year |
$3,440 3,440 gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $17,402 Cost: $25,229 |
$9,636 | 99,892 | $3,849 | 41 | $3,440 | 3,440 | $477 | - | $9,636 99,892 kWh |
$3,849 41 kW-months/year |
$3,440 3,440 gal |
$477 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,885 Cost: $1,637 |
$2,918 | 31,363 | $490 | 5 | - | - | $477 | - | $2,918 31,363 kWh |
$490 5 kW-months/year |
- - gal |
$477 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | One-time Revenue or Avoided Cost |