IAC logo
IAC Assessment: UF0513
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0513
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2017
Principal Product Apple and Citrus Flavors
NAICS 311423 - Dried and Dehydrated Food Manufacturing
SIC 2034 - Dehydrated Fruits, Vegetables, Soups
Sales $10,000,000-$50,000,000
# of Employees 54
Plant Area (Sq.Ft.) 49,295
Annual Production 26,566,000 Pounds
Production Hrs. Annual 4,992
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $106,099 1,837,840 kWh $0.06
Electricity Demand $37,833 4,855 kW-months/year $7.79
Electricity Fees $23,802 - $ -
Natural Gas $75,908 10,608 MMBtu $7.16
TOTAL ENERGY COSTS $243,643
RECOMMENDED SAVINGS* $103,314 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $58,802
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.1224 REPLACE BOILER Savings:
$38,664
Cost:
$30,000
- - - - $38,664 5,400 - - -
-
kWh
-
-
kW-months/year
$38,664
5,400
MMBtu
-
-
$
02: 2.2522 ISOLATE HOT OR COLD EQUIPMENT Savings:
$25,893
Cost:
$3,150
$25,893 454,272 - - - - - - $25,893
454,272
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$14,487
Cost:
$23,157
$14,487 254,160 - - - - - - $14,487
254,160
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.2312 MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS Savings:
$7,542
Cost:
-
- - - - $3,798 530 $3,744 - -
-
kWh
-
-
kW-months/year
$3,798
530
MMBtu
$3,744
-
$
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$6,342
Cost:
$27,695
$6,342 111,266 - - - - - - $6,342
111,266
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$5,848
Cost:
$10,386
$4,265 74,821 $1,583 203 - - - - $4,265
74,821
kWh
$1,583
203
kW-months/year
-
-
MMBtu
-
-
$
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$2,443
Cost:
$1,481
- - - - $2,443 341 - - -
-
kWh
-
-
kW-months/year
$2,443
341
MMBtu
-
-
$
08: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,095
Cost:
$5,053
$2,095 36,757 - - - - - - $2,095
36,757
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$103,314
Cost:
$100,922
$53,082 931,276 $1,583 203 $44,905 6,272 $3,744 - $53,082
931,276
kWh
$1,583
203
kW-months/year
$44,905
6,272
MMBtu
$3,744
-
$
TOTAL IMPLEMENTED Savings:
$58,802
Cost:
$60,536
$48,817 856,455 - - $6,241 872 $3,744 - $48,817
856,455
kWh
-
-
kW-months/year
$6,241
872
MMBtu
$3,744
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes