Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2018 |
Principal Product | Surgical and Medical Instruments and Apparatus |
NAICS | 339112 - Surgical and Medical Instrument Manufacturing |
SIC | 3841 - Surgical And Medical Instruments |
Sales | $10,000,000-$50,000,000 |
# of Employees | 818 |
Plant Area (Sq.Ft.) | 63,210 |
Annual Production | 10,000,000 Units |
Production Hrs. Annual | 6,256 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $391,169 | 5,588,135 | kWh | $0.07 |
Electricity Demand | $68,058 | 8,507 | kW-months/year | $8.00 |
Electricity Fees | $16,848 | - | $ | - |
Natural Gas | $17,894 | 7,334 | MMBtu | $2.44 |
TOTAL ENERGY COSTS | $552,737 | |||
RECOMMENDED SAVINGS* | $427,147 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $52,301 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3416 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST |
Savings: $120,914 Cost: $400,000 |
$131,376 | 1,876,800 | $28,800 | 3,600 | $(-37,200) | (-15,246) | - | - | $(-2,062) | - | - | - |
$131,376 1,876,800 kWh |
$28,800 3,600 kW-months/year |
$(-37,200) (-15,246) MMBtu |
- - $ |
$(-2,062) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $6,142 Cost: $18,013 |
$6,142 | 87,740 | - | - | - | - | - | - | - | - | - | - |
$6,142 87,740 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,159 Cost: $12,014 |
$3,167 | 45,246 | $992 | 123 | - | - | - | - | - | - | - | - |
$3,167 45,246 kWh |
$992 123 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.448 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM |
Savings: $200,000 Cost: $100,000 |
- | - | - | - | - | - | $42,000 | - | - | - | $158,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$42,000 - $ |
- - $ |
$158,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $42,000 Cost: $70,000 |
- | - | - | - | - | - | $42,000 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$42,000 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $30,207 Cost: $5,350 |
$(-97) | (-1,387) | $(-182) | (-23) | - | - | $8,112 | - | $22,374 | - | - | - |
$(-97) (-1,387) kWh |
$(-182) (-23) kW-months/year |
- - MMBtu |
$8,112 - $ |
$22,374 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $23,725 Cost: $10,695 |
- | - | - | - | - | - | $23,725 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$23,725 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $427,147 Cost: $616,072 |
$140,588 | 2,008,399 | $29,610 | 3,700 | $(-37,200) | (-15,246) | $115,837 | - | $20,312 | - | $158,000 | - | $140,588 2,008,399 kWh |
$29,610 3,700 kW-months/year |
$(-37,200) (-15,246) MMBtu |
$115,837 - $ |
$20,312 - $ |
$158,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $52,301 Cost: $100,027 |
$9,309 | 132,986 | $992 | 123 | - | - | $42,000 | - | - | - | - | - | $9,309 132,986 kWh |
$992 123 kW-months/year |
- - MMBtu |
$42,000 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | By-product Production |