Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2018 |
Principal Product | Orthopedic Prosthetic and Surgical Appliances and Supplies |
NAICS | 339113 - Surgical Appliance and Supplies Manufacturing |
SIC | 3842 - Surgical Appliances And Supplies |
Sales | $50,000,000-$100,000,000 |
# of Employees | 450 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 22,000 Units |
Production Hrs. Annual | 7,488 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $221,307 | 2,081,366 | kWh | $0.11 |
Electricity Demand | $47,924 | 5,484 | kW-months/year | $8.74 |
Electricity Fees | $31,209 | - | $ | - |
TOTAL ENERGY COSTS | $305,476 | |||
RECOMMENDED SAVINGS* | $150,102 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $150,102 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $24,028 Cost: $167,216 |
$24,028 | 226,678 | - | - | - | - | - | - |
$24,028 226,678 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $9,684 Cost: $1,980 |
$1,032 | 9,734 | $252 | 29 | $8,400 | - | - | - |
$1,032 9,734 kWh |
$252 29 kW-months/year |
$8,400 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR |
Savings: $3,844 Cost: $586 |
$3,844 | 36,263 | - | - | - | - | - | - |
$3,844 36,263 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,401 Cost: - |
$2,401 | 22,650 | - | - | - | - | - | - |
$2,401 22,650 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $1,145 Cost: $9,600 |
$1,145 | 10,804 | - | - | - | - | - | - |
$1,145 10,804 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $109,000 Cost: $41,200 |
- | - | - | - | - | - | $109,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$109,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $150,102 Cost: $220,582 |
$32,450 | 306,129 | $252 | 29 | $8,400 | - | $109,000 | - | $32,450 306,129 kWh |
$252 29 kW-months/year |
$8,400 - $ |
$109,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $150,102 Cost: $220,582 |
$32,450 | 306,129 | $252 | 29 | $8,400 | - | $109,000 | - | $32,450 306,129 kWh |
$252 29 kW-months/year |
$8,400 - $ |
$109,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost | One-time Revenue or Avoided Cost |