Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2020 |
Principal Product | Concrete Septic Tanks |
NAICS | 327320 - Ready-Mix Concrete Manufacturing |
SIC | 3273 - Ready-mixed Concrete |
Sales | $5,000,000-$10,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 4,900,000 |
Annual Production | 18,434 Tons |
Production Hrs. Annual | 2,860 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $14,241 | 191,497 | kWh | $0.07 |
Electricity Demand | $6,744 | 603 | kW-months/year | $11.18 |
Electricity Fees | $5,319 | - | $ | - |
Fuel Oil #2 | $142,749 | 7,578 | MMBtu | $18.84 |
TOTAL ENERGY COSTS | $169,053 | |||
RECOMMENDED SAVINGS* | $423,317 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $423,317 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | Fuel Oil #2 | One-time Revenue or Avoided Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8226 INCREASE EFFICIENCY OF TRUCKS |
Savings: $70,950 Cost: $336,000 |
- | - | - | - | $46,950 | 2,490 | $24,000 | - | - | - |
- - kWh |
- - kW-months/year |
$46,950 2,490 MMBtu |
$24,000 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,846 Cost: $7,217 |
$2,952 | 39,893 | $4,894 | 438 | - | - | - | - | - | - |
$2,952 39,893 kWh |
$4,894 438 kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,700 Cost: $10,047 |
$2,700 | 36,481 | - | - | - | - | - | - | - | - |
$2,700 36,481 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,821 Cost: $3,900 |
$581 | 7,849 | $1,240 | 111 | - | - | - | - | - | - |
$581 7,849 kWh |
$1,240 111 kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $340,000 Cost: $5,859 |
- | - | - | - | - | - | - | - | $340,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$340,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $423,317 Cost: $363,023 |
$6,233 | 84,223 | $6,134 | 548 | $46,950 | 2,490 | $24,000 | - | $340,000 | - | $6,233 84,223 kWh |
$6,134 548 kW-months/year |
$46,950 2,490 MMBtu |
$24,000 - $ |
$340,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $423,317 Cost: $363,023 |
$6,233 | 84,223 | $6,134 | 548 | $46,950 | 2,490 | $24,000 | - | $340,000 | - | $6,233 84,223 kWh |
$6,134 548 kW-months/year |
$46,950 2,490 MMBtu |
$24,000 - $ |
$340,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | Fuel Oil #2 | One-time Revenue or Avoided Cost | Increase in Production |