IAC Center | University of Florida |
---|---|
Assessment Year | 2020 |
Principal Product | Medical Furnishing |
NAICS | 337127 - Institutional Furniture Manufacturing |
SIC | 2599 - Furniture And Fixtures, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 31,890 Units |
Production Hrs. Annual | 3,134 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $44,471 | 642,415 | kWh | $0.07 |
Electricity Demand | $26,652 | 3,796 | kW-months/year | $7.02 |
Electricity Fees | $11,639 | - | $ | - |
Natural Gas | $18,767 | 3,439 | MMBtu | $5.46 |
TOTAL ENERGY COSTS | $101,529 | |||
RECOMMENDED SAVINGS* | $78,204 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $36,128 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $42,076 Cost: $359,360 |
$42,076 | 609,804 | - | - | - | - | - | - |
$42,076 609,804 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $19,566 Cost: $32,210 |
$(-33) | (-483) | - | - | - | - | $19,599 | - |
$(-33) (-483) kWh |
- - kW-months/year |
- - MMBtu |
$19,599 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,767 Cost: $956 |
$3,767 | 54,601 | - | - | - | - | - | - |
$3,767 54,601 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.5115 REPOSITION OVEN WALLS TO REDUCE HEATED SPACE |
Savings: $3,003 Cost: $750 |
- | - | - | - | $3,003 | 550 | - | - |
- - kWh |
- - kW-months/year |
$3,003 550 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,600 Cost: $3,317 |
$1,476 | 21,395 | $1,124 | 160 | - | - | - | - |
$1,476 21,395 kWh |
$1,124 160 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,328 Cost: $5,468 |
$956 | 13,852 | $372 | 53 | - | - | - | - |
$956 13,852 kWh |
$372 53 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $602 Cost: - |
$602 | 8,719 | - | - | - | - | - | - |
$602 8,719 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $5,262 Cost: $7,180 |
$(-6) | (-89) | $(-192) | (-27) | - | - | $5,460 | - |
$(-6) (-89) kWh |
$(-192) (-27) kW-months/year |
- - MMBtu |
$5,460 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $78,204 Cost: $409,241 |
$48,838 | 707,799 | $1,304 | 186 | $3,003 | 550 | $25,059 | - | $48,838 707,799 kWh |
$1,304 186 kW-months/year |
$3,003 550 MMBtu |
$25,059 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $36,128 Cost: $49,881 |
$6,762 | 97,995 | $1,304 | 186 | $3,003 | 550 | $25,059 | - | $6,762 97,995 kWh |
$1,304 186 kW-months/year |
$3,003 550 MMBtu |
$25,059 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Primary Product |