IAC Center | University of Florida |
---|---|
Assessment Year | 2020 |
Principal Product | Dehydration Equipment, Desiccant & Refrigerated Dryers |
NAICS | 333912 - Air and Gas Compressor Manufacturing |
SIC | 3563 - Air And Gas Compressors |
Sales | $50,000,000-$100,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 1,682 Units |
Production Hrs. Annual | 2,730 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $117,622 | 1,715,610 | kWh | $0.07 |
Electricity Demand | $64,638 | 7,983 | kW-months/year | $8.10 |
Electricity Fees | $22,703 | - | $ | - |
Natural Gas | $4,342 | 1,019 | MMBtu | $4.26 |
LPG | $15,212 | 370 | MMBtu | $41.07 |
TOTAL ENERGY COSTS | $226,757 | |||
RECOMMENDED SAVINGS* | $58,183 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,000 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Product | Electricity Usage | Electricity Demand | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $30,571 Cost: $24,600 |
$(-67) | (-973) | - | - | $30,638 | - |
$(-67) (-973) kWh |
- - kW-months/year |
$30,638 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $11,635 Cost: $4,086 |
$6,894 | 99,912 | $4,741 | 586 | - | - |
$6,894 99,912 kWh |
$4,741 586 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,271 Cost: - |
$4,271 | 61,903 | - | - | - | - |
$4,271 61,903 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS |
Savings: $3,128 Cost: $7,733 |
$3,128 | 45,334 | - | - | - | - |
$3,128 45,334 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,645 Cost: $4,780 |
$2,645 | 38,329 | - | - | - | - |
$2,645 38,329 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $2,545 Cost: $1,778 |
$2,545 | 36,877 | - | - | - | - |
$2,545 36,877 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $2,484 Cost: $2,380 |
$1,639 | 23,751 | $845 | 104 | - | - |
$1,639 23,751 kWh |
$845 104 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $904 Cost: - |
$904 | 13,104 | - | - | - | - |
$904 13,104 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $58,183 Cost: $45,357 |
$21,959 | 318,237 | $5,586 | 690 | $30,638 | - | $21,959 318,237 kWh |
$5,586 690 kW-months/year |
$30,638 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,000 Cost: $10,644 |
$17,259 | 250,125 | $4,741 | 586 | - | - | $17,259 250,125 kWh |
$4,741 586 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Product | Electricity Usage | Electricity Demand | Primary Product |