Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2021 |
Principal Product | Wastewater Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $10,000,000-$50,000,000 |
# of Employees | 14 |
Plant Area (Sq.Ft.) | 53,721 |
Annual Production | 1,896,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $386,572 | 8,173,800 | kWh | $0.05 |
Electricity Demand | $93,051 | 15,402 | kW-months/year | $6.04 |
Electricity Fees | $47,361 | - | $ | - |
TOTAL ENERGY COSTS | $526,984 | |||
RECOMMENDED SAVINGS* | $746,880 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $38,351 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Primary Product | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1336 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL |
Savings: $124,268 Cost: $90,000 |
$105,638 | 2,247,626 | $18,630 | 3,084 | - | - | - | - | - | - | - | - |
$105,638 2,247,626 kWh |
$18,630 3,084 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $120,536 Cost: $84,600 |
$93,061 | 1,980,014 | $27,475 | 4,548 | - | - | - | - | - | - | - | - |
$93,061 1,980,014 kWh |
$27,475 4,548 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $52,797 Cost: $9,223 |
$46,397 | 987,169 | $6,400 | 1,059 | - | - | - | - | - | - | - | - |
$46,397 987,169 kWh |
$6,400 1,059 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $32,569 Cost: $48,945 |
$32,569 | 692,963 | - | - | - | - | - | - | - | - | - | - |
$32,569 692,963 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $29,289 Cost: - |
$29,289 | 623,165 | - | - | - | - | - | - | - | - | - | - |
$29,289 623,165 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,587 Cost: $12,332 |
$2,587 | 55,041 | - | - | - | - | - | - | - | - | - | - |
$2,587 55,041 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,574 Cost: - |
$1,107 | 23,563 | - | - | $225 | - | $242 | - | - | - | - | - |
$1,107 23,563 kWh |
- - kW-months/year |
$225 - $ |
$242 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $381,639 Cost: $1,857,208 |
$(-5,147) | (-109,500) | $(-906) | (-150) | - | - | $304,492 | - | - | - | $83,200 | - |
$(-5,147) (-109,500) kWh |
$(-906) (-150) kW-months/year |
- - $ |
$304,492 - $ |
- - $ |
$83,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.662 LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS |
Savings: $1,621 Cost: - |
- | - | - | - | - | - | - | - | $1,621 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$1,621 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $746,880 Cost: $2,102,308 |
$305,501 | 6,500,041 | $51,599 | 8,541 | $225 | - | $304,734 | - | $1,621 | - | $83,200 | - | $305,501 6,500,041 kWh |
$51,599 8,541 kW-months/year |
$225 - $ |
$304,734 - $ |
$1,621 - $ |
$83,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $38,351 Cost: $61,277 |
$36,263 | 771,567 | - | - | $225 | - | $242 | - | $1,621 | - | - | - | $36,263 771,567 kWh |
- - kW-months/year |
$225 - $ |
$242 - $ |
$1,621 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Personnel Changes | Primary Raw Material | Primary Product | By-product Production |