Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2021 |
Principal Product | Wastewater Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $10,000,000-$50,000,000 |
# of Employees | 15 |
Plant Area (Sq.Ft.) | 344,000 |
Annual Production | 2,100,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $346,135 | 5,866,700 | kWh | $0.06 |
Electricity Demand | $91,836 | 15,306 | kW-months/year | $6.00 |
Electricity Fees | $6,817 | - | $ | - |
TOTAL ENERGY COSTS | $444,788 | |||
RECOMMENDED SAVINGS* | $1,779,569 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $38,101 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $52,474 Cost: $147,852 |
$41,127 | 697,073 | $11,347 | 1,891 | - | - | - | - | - | - | - | - |
$41,127 697,073 kWh |
$11,347 1,891 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS |
Savings: $20,147 Cost: $49,165 |
$20,147 | 341,473 | - | - | - | - | - | - | - | - | - | - |
$20,147 341,473 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $11,182 Cost: $12,247 |
$8,997 | 152,496 | $2,185 | 364 | - | - | - | - | - | - | - | - |
$8,997 152,496 kWh |
$2,185 364 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.5195 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS |
Savings: $8,146 Cost: $700 |
$8,146 | 138,060 | - | - | - | - | - | - | - | - | - | - |
$8,146 138,060 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,117 Cost: $9,240 |
$3,117 | 52,838 | - | - | - | - | - | - | - | - | - | - |
$3,117 52,838 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.5121 REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH |
Savings: $1,828 Cost: - |
$1,828 | 30,979 | - | - | - | - | - | - | - | - | - | - |
$1,828 30,979 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $1,670,260 Cost: $53,000 |
$(-18,761) | (-317,988) | $(-2,614) | (-436) | $(-80,424) | (-6,000) | - | - | - | - | $1,772,059 | - |
$(-18,761) (-317,988) kWh |
$(-2,614) (-436) kW-months/year |
$(-80,424) (-6,000) MMBtu |
- - $ |
- - $ |
$1,772,059 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $8,760 Cost: $8,000 |
- | - | - | - | - | - | $8,760 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$8,760 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.662 LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS |
Savings: $3,655 Cost: - |
- | - | - | - | - | - | - | - | $3,655 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$3,655 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,779,569 Cost: $280,204 |
$64,601 | 1,094,931 | $10,918 | 1,819 | $(-80,424) | (-6,000) | $8,760 | - | $3,655 | - | $1,772,059 | - | $64,601 1,094,931 kWh |
$10,918 1,819 kW-months/year |
$(-80,424) (-6,000) MMBtu |
$8,760 - $ |
$3,655 - $ |
$1,772,059 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $38,101 Cost: $70,652 |
$32,261 | 546,807 | $2,185 | 364 | - | - | - | - | $3,655 | - | - | - | $32,261 546,807 kWh |
$2,185 364 kW-months/year |
- - MMBtu |
- - $ |
$3,655 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | By-product Production |