Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2022 |
Principal Product | Lithium-ion Batteries |
NAICS | 335911 - Storage Battery Manufacturing |
SIC | 3691 - Storage Batteries |
Sales | $10,000,000-$50,000,000 |
# of Employees | 25 |
Plant Area (Sq.Ft.) | 240,000 |
Annual Production | 6,417 Units |
Production Hrs. Annual | 3,000 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $626,056 | 11,906,395 | kWh | $0.05 |
Electricity Demand | $213,430 | 32,449 | kW-months/year | $6.58 |
Electricity Fees | $127,411 | - | $ | - |
Natural Gas | $238,445 | 30,910 | MMBtu | $7.71 |
TOTAL ENERGY COSTS | $1,222,949 | |||
RECOMMENDED SAVINGS* | $766,653 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $586,028 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $320,724 Cost: $1,068,750 |
$450,500 | 8,500,000 | $78,924 | 12,000 | $(-123,700) | (-18,808) | $(-85,000) | - | - | - |
$450,500 8,500,000 kWh |
$78,924 12,000 kW-months/year |
$(-123,700) (-18,808) MMBtu |
$(-85,000) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER |
Savings: $175,432 Cost: - |
- | - | - | - | - | - | $175,432 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$175,432 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $59,112 Cost: $64,054 |
$44,173 | 833,448 | $14,939 | 2,271 | - | - | - | - | - | - |
$44,173 833,448 kWh |
$14,939 2,271 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $5,193 Cost: $12,000 |
$3,573 | 67,408 | $1,620 | 246 | - | - | - | - | - | - |
$3,573 67,408 kWh |
$1,620 246 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,361 Cost: - |
$3,361 | 63,410 | - | - | - | - | - | - | - | - |
$3,361 63,410 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,831 Cost: $290 |
$2,831 | 53,414 | - | - | - | - | - | - | - | - |
$2,831 53,414 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.662 LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS |
Savings: $200,000 Cost: - |
- | - | - | - | - | - | - | - | $200,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$200,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $766,653 Cost: $1,145,094 |
$504,438 | 9,517,680 | $95,483 | 14,518 | $(-123,700) | (-18,808) | $90,432 | - | $200,000 | - | $504,438 9,517,680 kWh |
$95,483 14,518 kW-months/year |
$(-123,700) (-18,808) MMBtu |
$90,432 - $ |
$200,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $586,028 Cost: $1,133,094 |
$500,865 | 9,450,272 | $93,863 | 14,271 | $(-123,700) | (-18,808) | $(-85,000) | - | $200,000 | - | $500,865 9,450,272 kWh |
$93,863 14,271 kW-months/year |
$(-123,700) (-18,808) MMBtu |
$(-85,000) - $ |
$200,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Raw Material |