Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2022
Principal Product Printing Products and Flexible Packaging
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 2752 - Commercial Printing, Lithographic
Sales $10,000,000-$50,000,000
# of Employees 80
Plant Area (Sq.Ft.) 43,500
Annual Production 61,673,991 Units
Production Hrs. Annual 5,928
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $83,712 1,228,164 kWh $0.07
Electricity Demand $48,079 4,225 kW-months/year $11.38
Electricity Fees $13,530 - $ -
TOTAL ENERGY COSTS $426,803
RECOMMENDED SAVINGS* $155,024 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $59,592
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Electricity Usage Electricity Demand Personnel Changes
$ kWh $ kW-months/year $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$86,172
Cost:
$297,040
$42,473 624,597 $43,699 3,840 - - $42,473
624,597
kWh
$43,699
3,840
kW-months/year
-
-
$
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$23,066
Cost:
$12,420
$(-1,415) (-20,811) $(-479) (-42) $24,960 - $(-1,415)
(-20,811)
kWh
$(-479)
(-42)
kW-months/year
$24,960
-
$
03: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$9,260
Cost:
$6,608
$5,846 85,971 $3,414 300 - - $5,846
85,971
kWh
$3,414
300
kW-months/year
-
-
$
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$6,260
Cost:
$25,400
$6,260 92,055 - - - - $6,260
92,055
kWh
-
-
kW-months/year
-
-
$
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$5,306
Cost:
$9,876
$2,575 37,872 $2,731 240 - - $2,575
37,872
kWh
$2,731
240
kW-months/year
-
-
$
06: 4.424 IMPROVE SPACE COMFORT CONDITIONING Savings:
$24,960
Cost:
$4,480
- - - - $24,960 - -
-
kWh
-
-
kW-months/year
$24,960
-
$
TOTAL RECOMMENDED Savings:
$155,024
Cost:
$355,824
$55,739 819,684 $49,365 4,338 $49,920 - $55,739
819,684
kWh
$49,365
4,338
kW-months/year
$49,920
-
$
TOTAL IMPLEMENTED Savings:
$59,592
Cost:
$52,176
$7,420 109,116 $2,252 198 $49,920 - $7,420
109,116
kWh
$2,252
198
kW-months/year
$49,920
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Personnel Changes Electricity Usage Electricity Demand Personnel Changes