Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2023 |
Principal Product | Surgical & Medical Instruments |
NAICS | 334519 - Other Measuring and Controlling Device Manufacturing |
SIC | 3841 - Surgical And Medical Instruments |
Sales | $50,000,000-$100,000,000 |
# of Employees | 420 |
Plant Area (Sq.Ft.) | 258,000 |
Annual Production | 55,000,000 Units |
Production Hrs. Annual | 7,488 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,221,190 | 17,125,093 | kWh | $0.07 |
Electricity Demand | $360,943 | 89,823 | kW-months/year | $4.02 |
Electricity Fees | $89,347 | - | $ | - |
TOTAL ENERGY COSTS | $1,923,856 | |||
RECOMMENDED SAVINGS* | $656,169 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $630,342 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3113 MAKE ICE DURING OFF PEAK HOURS FOR COOLING |
Savings: $131,807 Cost: $215,600 |
$44,182 | 622,282 | - | - | - | - | $87,625 | - | - | - |
$44,182 622,282 kWh |
- - kW-months/year |
- - $ |
$87,625 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $110,377 Cost: $92,132 |
$85,112 | 1,198,757 | $25,265 | 6,288 | - | - | - | - | - | - |
$85,112 1,198,757 kWh |
$25,265 6,288 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $97,641 Cost: $400,000 |
$87,713 | 1,235,400 | $9,928 | 2,471 | - | - | - | - | - | - |
$87,713 1,235,400 kWh |
$9,928 2,471 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $64,641 Cost: $136,253 |
$59,583 | 839,200 | $5,058 | 1,259 | - | - | - | - | - | - |
$59,583 839,200 kWh |
$5,058 1,259 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $62,208 Cost: $25,500 |
$62,208 | 876,167 | - | - | - | - | - | - | - | - |
$62,208 876,167 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL |
Savings: $25,827 Cost: $58,363 |
$(-2,485) | (-35,000) | $(-1,688) | (-420) | - | - | $30,000 | - | - | - |
$(-2,485) (-35,000) kWh |
$(-1,688) (-420) kW-months/year |
- - $ |
$30,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $5,604 Cost: - |
$4,452 | 62,708 | - | - | $588 | - | - | - | $564 | - |
$4,452 62,708 kWh |
- - kW-months/year |
$588 - $ |
- - $ |
$564 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.661 LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT |
Savings: $121,588 Cost: $12,000 |
$121,588 | 1,712,509 | - | - | - | - | - | - | - | - |
$121,588 1,712,509 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.664 LEVEL THREE - INSTALL OR MODIFY CONTROL SYSTEM WITH COMMUNICATION AND NONLOCAL EXTERNAL INFORMATION (I.E. WEATHER FORECA |
Savings: $36,476 Cost: $11,225 |
$36,476 | 513,753 | - | - | - | - | - | - | - | - |
$36,476 513,753 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $656,169 Cost: $951,073 |
$498,829 | 7,025,776 | $38,563 | 9,598 | $588 | - | $117,625 | - | $564 | - | $498,829 7,025,776 kWh |
$38,563 9,598 kW-months/year |
$588 - $ |
$117,625 - $ |
$564 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $630,342 Cost: $892,710 |
$501,314 | 7,060,776 | $40,251 | 10,018 | $588 | - | $87,625 | - | $564 | - | $501,314 7,060,776 kWh |
$40,251 10,018 kW-months/year |
$588 - $ |
$87,625 - $ |
$564 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost |