IAC logo
IAC Assessment: UF0599
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0599
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2023
Principal Product Cement Backer Boards
NAICS 327420 - Gypsum Product Manufacturing
SIC 3275 - Gypsum Products
Sales $10,000,000-$50,000,000
# of Employees 40
Plant Area (Sq.Ft.) 350,000
Annual Production 600,000,000 Units
Production Hrs. Annual 8,760
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $104,411 1,701,840 kWh $0.06
Electricity Demand $27,911 3,282 kW-months/year $8.50
Electricity Fees $118,982 - $ -
LPG $149,305 612 MMBtu $243.82
TOTAL ENERGY COSTS $400,609
RECOMMENDED SAVINGS* $277,823 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand LPG Administrative Changes Electricity Usage Electricity Demand LPG Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$74,653
Cost:
-
- - - - - - $74,653 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$74,653
-
$
02: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT Savings:
$57,942
Cost:
$18,000
- - - - $57,942 238 - - -
-
kWh
-
-
kW-months/year
$57,942
238
MMBtu
-
-
$
03: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL Savings:
$39,593
Cost:
$8,330
$(-305) (-5,000) $(-102) (-12) - - $40,000 - $(-305)
(-5,000)
kWh
$(-102)
(-12)
kW-months/year
-
-
MMBtu
$40,000
-
$
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$31,388
Cost:
$12,420
$(-357) (-5,845) $(-287) (-34) - - $32,032 - $(-357)
(-5,845)
kWh
$(-287)
(-34)
kW-months/year
-
-
MMBtu
$32,032
-
$
05: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$13,170
Cost:
$9,156
$10,381 170,184 $2,789 328 - - - - $10,381
170,184
kWh
$2,789
328
kW-months/year
-
-
MMBtu
-
-
$
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,242
Cost:
$9,619
$6,242 102,333 - - - - - - $6,242
102,333
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,225
Cost:
$412
$6,225 102,053 - - - - - - $6,225
102,053
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$4,851
Cost:
$24,000
$3,469 56,873 $1,382 162 - - - - $3,469
56,873
kWh
$1,382
162
kW-months/year
-
-
MMBtu
-
-
$
09: 2.1222 INSTALL TURBULATORS Savings:
$4,318
Cost:
$5,000
- - - - $4,318 18 - - -
-
kWh
-
-
kW-months/year
$4,318
18
MMBtu
-
-
$
10: 4.424 IMPROVE SPACE COMFORT CONDITIONING Savings:
$34,250
Cost:
$2,384
$(-527) (-8,632) $(-538) (-63) - - $35,315 - $(-527)
(-8,632)
kWh
$(-538)
(-63)
kW-months/year
-
-
MMBtu
$35,315
-
$
11: 4.664 LEVEL THREE - INSTALL OR MODIFY CONTROL SYSTEM WITH COMMUNICATION AND NONLOCAL EXTERNAL INFORMATION (I.E. WEATHER FORECA Savings:
$5,191
Cost:
$11,500
$5,191 85,092 - - - - - - $5,191
85,092
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$277,823
Cost:
$100,821
$30,319 497,058 $3,244 382 $62,260 255 $182,000 - $30,319
497,058
kWh
$3,244
382
kW-months/year
$62,260
255
MMBtu
$182,000
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand LPG Administrative Changes Electricity Usage Electricity Demand LPG Administrative Changes