Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2023 |
Principal Product | Cement Backer Boards |
NAICS | 327420 - Gypsum Product Manufacturing |
SIC | 3275 - Gypsum Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 40 |
Plant Area (Sq.Ft.) | 350,000 |
Annual Production | 600,000,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $104,411 | 1,701,840 | kWh | $0.06 |
Electricity Demand | $27,911 | 3,282 | kW-months/year | $8.50 |
Electricity Fees | $118,982 | - | $ | - |
LPG | $149,305 | 612 | MMBtu | $243.82 |
TOTAL ENERGY COSTS | $400,609 | |||
RECOMMENDED SAVINGS* | $277,823 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $184,809 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $74,653 Cost: - |
- | - | - | - | - | - | $74,653 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$74,653 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $57,942 Cost: $18,000 |
- | - | - | - | $57,942 | 238 | - | - |
- - kWh |
- - kW-months/year |
$57,942 238 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL |
Savings: $39,593 Cost: $8,330 |
$(-305) | (-5,000) | $(-102) | (-12) | - | - | $40,000 | - |
$(-305) (-5,000) kWh |
$(-102) (-12) kW-months/year |
- - MMBtu |
$40,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $31,388 Cost: $12,420 |
$(-357) | (-5,845) | $(-287) | (-34) | - | - | $32,032 | - |
$(-357) (-5,845) kWh |
$(-287) (-34) kW-months/year |
- - MMBtu |
$32,032 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $13,170 Cost: $9,156 |
$10,381 | 170,184 | $2,789 | 328 | - | - | - | - |
$10,381 170,184 kWh |
$2,789 328 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,242 Cost: $9,619 |
$6,242 | 102,333 | - | - | - | - | - | - |
$6,242 102,333 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,225 Cost: $412 |
$6,225 | 102,053 | - | - | - | - | - | - |
$6,225 102,053 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,851 Cost: $24,000 |
$3,469 | 56,873 | $1,382 | 162 | - | - | - | - |
$3,469 56,873 kWh |
$1,382 162 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1222 INSTALL TURBULATORS |
Savings: $4,318 Cost: $5,000 |
- | - | - | - | $4,318 | 18 | - | - |
- - kWh |
- - kW-months/year |
$4,318 18 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $34,250 Cost: $2,384 |
$(-527) | (-8,632) | $(-538) | (-63) | - | - | $35,315 | - |
$(-527) (-8,632) kWh |
$(-538) (-63) kW-months/year |
- - MMBtu |
$35,315 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.664 LEVEL THREE - INSTALL OR MODIFY CONTROL SYSTEM WITH COMMUNICATION AND NONLOCAL EXTERNAL INFORMATION (I.E. WEATHER FORECA |
Savings: $5,191 Cost: $11,500 |
$5,191 | 85,092 | - | - | - | - | - | - |
$5,191 85,092 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $277,823 Cost: $100,821 |
$30,319 | 497,058 | $3,244 | 382 | $62,260 | 255 | $182,000 | - | $30,319 497,058 kWh |
$3,244 382 kW-months/year |
$62,260 255 MMBtu |
$182,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $184,809 Cost: $80,165 |
$14,747 | 241,782 | $455 | 54 | $62,260 | 255 | $107,347 | - | $14,747 241,782 kWh |
$455 54 kW-months/year |
$62,260 255 MMBtu |
$107,347 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes |