Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2023 |
Principal Product | Asphalt Cement |
NAICS | 324121 - Asphalt Paving Mixture and Block Manufacturing |
SIC | 2951 - Asphalt Paving Mixtures And Blocks |
Sales | $50,000,000-$100,000,000 |
# of Employees | 9 |
Plant Area (Sq.Ft.) | 813,544 |
Annual Production | 90,000 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $101,613 | 1,153,600 | kWh | $0.09 |
Electricity Demand | $62,661 | 4,466 | kW-months/year | $14.03 |
Electricity Fees | $35,421 | - | $ | - |
Natural Gas | $86,953 | 15,370 | MMBtu | $5.66 |
TOTAL ENERGY COSTS | $286,648 | |||
RECOMMENDED SAVINGS* | $1,613,601 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,505,179 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $108,422 Cost: $322,608 |
$54,543 | 619,806 | $53,879 | 3,840 | - | - | - | - |
$54,543 619,806 kWh |
$53,879 3,840 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $38,052 Cost: $10,000 |
- | - | - | - | $38,052 | 6,727 | - | - |
- - kWh |
- - kW-months/year |
$38,052 6,727 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $13,825 Cost: $11,200 |
$8,213 | 93,331 | $5,612 | 400 | - | - | - | - |
$8,213 93,331 kWh |
$5,612 400 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $3,043 Cost: $2,800 |
- | - | - | - | $3,043 | 538 | - | - |
- - kWh |
- - kW-months/year |
$3,043 538 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.662 LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS |
Savings: $1,444,605 Cost: - |
- | - | - | - | - | - | $1,444,605 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,444,605 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.661 LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT |
Savings: $5,654 Cost: $20,000 |
$3,046 | 34,608 | - | - | $2,608 | 461 | - | - |
$3,046 34,608 kWh |
- - kW-months/year |
$2,608 461 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,613,601 Cost: $366,608 |
$65,802 | 747,745 | $59,491 | 4,240 | $43,703 | 7,726 | $1,444,605 | - | $65,802 747,745 kWh |
$59,491 4,240 kW-months/year |
$43,703 7,726 MMBtu |
$1,444,605 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,505,179 Cost: $44,000 |
$11,259 | 127,939 | $5,612 | 400 | $43,703 | 7,726 | $1,444,605 | - | $11,259 127,939 kWh |
$5,612 400 kW-months/year |
$43,703 7,726 MMBtu |
$1,444,605 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |