Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2024 |
Principal Product | Radiation Therapy Devices |
NAICS | 339113 - Surgical Appliance and Supplies Manufacturing |
SIC | 3841 - Surgical And Medical Instruments |
Sales | $5,000,000-$10,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 35,000 |
Annual Production | 484,773 Units |
Production Hrs. Annual | 4,940 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $73,908 | 1,087,200 | kWh | $0.07 |
Electricity Demand | $34,191 | 2,685 | kW-months/year | $12.73 |
Electricity Fees | $18,889 | - | $ | - |
TOTAL ENERGY COSTS | $126,988 | |||
RECOMMENDED SAVINGS* | $121,814 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $80,652 Cost: $322,608 |
$43,978 | 646,737 | $36,674 | 2,880 | - | - | - | - | - | - |
$43,978 646,737 kWh |
$36,674 2,880 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $21,638 Cost: $12,552 |
$(-248) | (-3,650) | $(-536) | (-42) | - | - | $22,422 | - | - | - |
$(-248) (-3,650) kWh |
$(-536) (-42) kW-months/year |
- - $ |
$22,422 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $7,571 Cost: $5,849 |
$5,175 | 76,104 | $2,396 | 188 | - | - | - | - | - | - |
$5,175 76,104 kWh |
$2,396 188 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $5,125 Cost: $25,440 |
$2,793 | 41,076 | $2,332 | 183 | - | - | - | - | - | - |
$2,793 41,076 kWh |
$2,332 183 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,749 Cost: $327 |
$1,749 | 25,723 | - | - | - | - | - | - | - | - |
$1,749 25,723 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $1,368 Cost: $202 |
$1,368 | 20,123 | - | - | - | - | - | - | - | - |
$1,368 20,123 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7421 REDUCE GLAZED AREAS IN BUILDINGS |
Savings: $1,097 Cost: $1,075 |
$1,097 | 16,129 | - | - | - | - | - | - | - | - |
$1,097 16,129 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,073 Cost: - |
$644 | 9,467 | - | - | $248 | - | - | - | $181 | - |
$644 9,467 kWh |
- - kW-months/year |
$248 - $ |
- - $ |
$181 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,015 Cost: - |
$1,015 | 14,925 | - | - | - | - | - | - | - | - |
$1,015 14,925 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $526 Cost: $1,500 |
$526 | 7,739 | - | - | - | - | - | - | - | - |
$526 7,739 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $121,814 Cost: $369,553 |
$58,097 | 854,373 | $40,866 | 3,209 | $248 | - | $22,422 | - | $181 | - | $58,097 854,373 kWh |
$40,866 3,209 kW-months/year |
$248 - $ |
$22,422 - $ |
$181 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost |