Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2024 |
Principal Product | Biobased Fertilizers |
NAICS | 325311 - Nitrogenous Fertilizer Manufacturing |
SIC | 2873 - Nitrogenous Fertilizers |
Sales | $1,000,000-$5,000,000 |
# of Employees | 20 |
Plant Area (Sq.Ft.) | 50,970 |
Annual Production | 10,000 Tons |
Production Hrs. Annual | 2,250 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $13,278 | 162,000 | kWh | $0.08 |
Electricity Demand | $4,615 | 1,056 | kW-months/year | $4.37 |
Electricity Fees | $2,003 | - | $ | - |
Natural Gas | $14,714 | 1,050 | MMBtu | $14.01 |
LPG | $11,758 | 225 | MMBtu | $52.33 |
Fuel Oil #2 | $63,095 | 2,238 | MMBtu | $28.20 |
TOTAL ENERGY COSTS | $109,463 | |||
RECOMMENDED SAVINGS* | $503,151 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $19,157 Cost: $112,913 |
$13,284 | 162,000 | $5,873 | 1,344 | - | - | - | - | - | - | - | - |
$13,284 162,000 kWh |
$5,873 1,344 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $1,789 Cost: $872 |
$1,328 | 16,200 | $461 | 106 | - | - | - | - | - | - | - | - |
$1,328 16,200 kWh |
$461 106 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,409 Cost: $5,855 |
$682 | 8,319 | $727 | 166 | - | - | - | - | - | - | - | - |
$682 8,319 kWh |
$727 166 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.114 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS |
Savings: $308,175 Cost: $14,388 |
- | - | - | - | $8,175 | 583 | - | - | $300,000 | - | - | - |
- - kWh |
- - kW-months/year |
$8,175 583 MMBtu |
- - $ |
$300,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.211 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE |
Savings: $150,000 Cost: $70,000 |
- | - | - | - | - | - | - | - | - | - | $150,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$150,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $12,621 Cost: $12,380 |
$(-299) | (-3,650) | $(-184) | (-42) | - | - | $13,104 | - | - | - | - | - |
$(-299) (-3,650) kWh |
$(-184) (-42) kW-months/year |
- - MMBtu |
$13,104 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $10,000 Cost: $1,931 |
$(-299) | (-3,650) | $(-184) | (-42) | - | - | - | - | $10,483 | - | - | - |
$(-299) (-3,650) kWh |
$(-184) (-42) kW-months/year |
- - MMBtu |
- - $ |
$10,483 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $503,151 Cost: $218,339 |
$14,696 | 179,219 | $6,693 | 1,532 | $8,175 | 583 | $13,104 | - | $310,483 | - | $150,000 | - | $14,696 179,219 kWh |
$6,693 1,532 kW-months/year |
$8,175 583 MMBtu |
$13,104 - $ |
$310,483 - $ |
$150,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||