IAC logo
IAC Assessment: UK1510
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: UK1510
IAC Center University of Kentucky
Assessment Year 2015
Principal Product Fire Turnout Gear
NAICS 315220 - Men’s and Boys’ Cut and Sew Apparel Manufacturing
SIC 2326 - Men's and Boys' Work Clothing
Sales $10,000,000-$50,000,000
# of Employees 70
Plant Area (Sq.Ft.) 240,000
Annual Production 321,250 Pieces
Production Hrs. Annual 7,488
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $46,088 694,848 kWh $0.07
Electricity Demand $18,388 2,438 kW-months/year $7.54
Electricity Fees $7,520 - $ -
Natural Gas $42,072 2,855 MMBtu $14.74
TOTAL ENERGY COSTS $114,068
RECOMMENDED SAVINGS* $23,890 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,621
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$10,047
Cost:
$6,250
$8,494 128,691 $1,553 206 - - - - $8,494
128,691
kWh
$1,553
206
kW-months/year
-
-
MMBtu
-
-
$
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$3,354
Cost:
$750
$3,354 50,812 - - - - - - $3,354
50,812
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,580
Cost:
$2,360
$870 13,175 $135 18 - - $1,575 - $870
13,175
kWh
$135
18
kW-months/year
-
-
MMBtu
$1,575
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,187
Cost:
$2,890
$1,667 25,247 $520 69 - - - - $1,667
25,247
kWh
$520
69
kW-months/year
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,527
Cost:
$2,143
$1,241 18,796 $264 35 - - $22 - $1,241
18,796
kWh
$264
35
kW-months/year
-
-
MMBtu
$22
-
$
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,236
Cost:
-
$1,236 18,720 - - - - - - $1,236
18,720
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$849
Cost:
-
$849 12,849 - - - - - - $849
12,849
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
08: 2.4152 USE ONLY CERTIFIED MOTOR REPAIR SHOPS Savings:
$623
Cost:
$2,031
$623 9,435 - - - - - - $623
9,435
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$445
Cost:
$650
$445 6,740 - - - - - - $445
6,740
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
10: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$305
Cost:
$886
$305 4,617 - - - - - - $305
4,617
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
11: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$427
Cost:
$273
- - - - $427 29 - - -
-
kWh
-
-
kW-months/year
$427
29
MMBtu
-
-
$
12: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$310
Cost:
$90
- - - - $310 21 - - -
-
kWh
-
-
kW-months/year
$310
21
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$23,890
Cost:
$18,323
$19,084 289,082 $2,472 328 $737 50 $1,597 - $19,084
289,082
kWh
$2,472
328
kW-months/year
$737
50
MMBtu
$1,597
-
$
TOTAL IMPLEMENTED Savings:
$11,621
Cost:
$8,506
$8,368 126,750 $919 122 $737 50 $1,597 - $8,368
126,750
kWh
$919
122
kW-months/year
$737
50
MMBtu
$1,597
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost