Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Kentucky |
---|---|
Assessment Year | 2017 |
Principal Product | Trailer Suspension Systems |
NAICS | 336330 - Motor Vehicle Steering and Suspension Components (except Spring) Manufacturing |
SIC | 3537 - Industrial Trucks And Tractors |
Sales | $10,000,000-$50,000,000 |
# of Employees | 330 |
Plant Area (Sq.Ft.) | 105,000 |
Annual Production | 1,000,000 Units |
Production Hrs. Annual | 3,640 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $207,317 | 2,752,600 | kWh | $0.08 |
Electricity Demand | $45,091 | 5,900 | kW-months/year | $7.64 |
Electricity Fees | $1,310 | - | $ | - |
Natural Gas | $93,967 | 8,595 | MMBtu | $10.93 |
TOTAL ENERGY COSTS | $360,616 | |||
RECOMMENDED SAVINGS* | $55,567 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $22,720 Cost: $38,000 |
$15,374 | 204,173 | $7,346 | 962 | - | - | - | - |
$15,374 204,173 kWh |
$7,346 962 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,900 Cost: - |
$2,900 | 38,518 | - | - | - | - | - | - |
$2,900 38,518 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,934 Cost: $3,000 |
$1,934 | 25,679 | - | - | - | - | - | - |
$1,934 25,679 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7145 INSTALL SKYLIGHTS |
Savings: $9,639 Cost: $11,580 |
$9,639 | 128,007 | - | - | - | - | - | - |
$9,639 128,007 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,475 Cost: $3,350 |
$1,154 | 15,330 | $321 | 42 | - | - | - | - |
$1,154 15,330 kWh |
$321 42 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $841 Cost: $72 |
$630 | 8,372 | $211 | 27 | - | - | - | - |
$630 8,372 kWh |
$211 27 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $6,376 Cost: $3,000 |
- | - | - | - | $6,376 | 583 | - | - |
- - kWh |
- - kW-months/year |
$6,376 583 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $3,221 Cost: $7,597 |
- | - | - | - | $3,221 | 295 | - | - |
- - kWh |
- - kW-months/year |
$3,221 295 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $1,810 Cost: $3,352 |
- | - | - | - | $1,810 | 166 | - | - |
- - kWh |
- - kW-months/year |
$1,810 166 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $835 Cost: - |
$835 | 11,083 | - | - | - | - | - | - |
$835 11,083 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $1,333 Cost: - |
- | - | - | - | $1,333 | 122 | - | - |
- - kWh |
- - kW-months/year |
$1,333 122 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,083 Cost: $1,584 |
- | - | - | - | $1,083 | 99 | - | - |
- - kWh |
- - kW-months/year |
$1,083 99 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $1,400 Cost: $422 |
- | - | - | - | - | - | $1,400 | 350 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,400 350 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $55,567 Cost: $71,957 |
$32,466 | 431,162 | $7,878 | 1,031 | $13,823 | 1,265 | $1,400 | 350 | $32,466 431,162 kWh |
$7,878 1,031 kW-months/year |
$13,823 1,265 MMBtu |
$1,400 350 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |