Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Kentucky |
---|---|
Assessment Year | 2019 |
Principal Product | Ammunition Containers |
NAICS | 332439 - Other Metal Container Manufacturing |
SIC | 3499 - Fabricated Metal Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 75,000 |
Annual Production | 140,000 Pieces |
Production Hrs. Annual | 1,960 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $73,428 | 2,137,920 | kWh | $0.03 |
Electricity Demand | $266,968 | 14,799 | kW-months/year | $18.04 |
Electricity Fees | $2,527 | - | $ | - |
Natural Gas | $200,010 | 30,941 | MMBtu | $6.46 |
TOTAL ENERGY COSTS | $670,081 | |||
RECOMMENDED SAVINGS* | $227,060 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Usage | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Usage | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,711 Cost: $2,510 |
$875 | 25,725 | $2,836 | 156 | - | - | - | - | - | - | - | - |
$875 25,725 kWh |
$2,836 156 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1122 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT |
Savings: $7,951 Cost: $17,032 |
$(-624) | (-18,346) | $(-2,039) | (-113) | - | - | $10,614 | 1,643 | - | - | - | - |
$(-624) (-18,346) kWh |
$(-2,039) (-113) kW-months/year |
- - $ |
$10,614 1,643 MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $259 Cost: $260 |
$259 | 7,629 | - | - | - | - | - | - | - | - | - | - |
$259 7,629 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $19,983 Cost: $21,695 |
$4,956 | 145,752 | $15,027 | 833 | - | - | - | - | - | - | - | - |
$4,956 145,752 kWh |
$15,027 833 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4159 REPLACE TREATED WATER WITH WELL / SURFACE WATER |
Savings: $53,903 Cost: $10,200 |
$(-597) | (-17,546) | $(-1,948) | (-108) | - | - | - | - | $24,696 | 7,056 | $31,752 | 7,056 |
$(-597) (-17,546) kWh |
$(-1,948) (-108) kW-months/year |
- - $ |
- - MMBtu |
$24,696 7,056 Tgal |
$31,752 7,056 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $13,534 Cost: $26,305 |
- | - | - | - | - | - | $13,534 | 2,095 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$13,534 2,095 MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $127,719 Cost: $54,495 |
- | - | - | - | $127,719 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$127,719 - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $227,060 Cost: $132,497 |
$4,869 | 143,214 | $13,876 | 768 | $127,719 | - | $24,148 | 3,738 | $24,696 | 7,056 | $31,752 | 7,056 | $4,869 143,214 kWh |
$13,876 768 kW-months/year |
$127,719 - $ |
$24,148 3,738 MMBtu |
$24,696 7,056 Tgal |
$31,752 7,056 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||