IAC Center | University of Louisville |
---|---|
Assessment Year | 1995 |
Principal Product | Offset Printing for Compact Disc sleeves |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $50,000,000-$100,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 18,000,000 Pieces |
Production Hrs. Annual | 7,774 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $301,762 | 5,357,269 | kWh | $0.06 |
Natural Gas | $73,791 | 19,191 | MMBtu | $3.85 |
TOTAL ENERGY COSTS | $429,938 | |||
RECOMMENDED SAVINGS* | $104,766 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Other Liquid (non-haz) | Electricity Usage | Other Liquid (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,392 Cost: $40 |
$2,392 | 59,789 | - | - |
$2,392 59,789 kWh |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,652 Cost: $4,124 |
$1,652 | 31,067 | - | - |
$1,652 31,067 kWh |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,025 Cost: $1,429 |
$4,025 | 75,909 | - | - |
$4,025 75,909 kWh |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $40,228 Cost: $19,553 |
$40,228 | - | - | - |
$40,228 - kWh |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5121 RECYCLE WASTE INK AND CLEANUP SOLVENT |
Savings: $18,324 Cost: - |
- | - | $18,324 | 1,695 |
- - kWh |
$18,324 1,695 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5121 RECYCLE WASTE INK AND CLEANUP SOLVENT |
Savings: $38,145 Cost: - |
- | - | $38,145 | 13,562 |
- - kWh |
$38,145 13,562 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $104,766 Cost: $25,146 |
$48,297 | 166,765 | $56,469 | 15,257 | $48,297 166,765 kWh |
$56,469 15,257 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - - kWh |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Other Liquid (non-haz) | Electricity Usage | Other Liquid (non-haz) |