Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1996 |
Principal Product | Automative Exhaust Systems |
NAICS | n/a |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 85,000 |
Annual Production | 320,000 Pieces |
Production Hrs. Annual | 6,624 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $125,424 | 6,004,103 | kWh | $0.02 |
Electricity Demand | $92,375 | 13,258 | kW-months/year | $6.97 |
Electricity Fees | $2,052 | - | $ | - |
Natural Gas | $61,368 | 18,603 | MMBtu | $3.30 |
TOTAL ENERGY COSTS | $594,219 | |||
RECOMMENDED SAVINGS* | $210,289 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,289 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $27,420 Cost: $2,000 |
- | - | - | - | $27,420 | 8,309 | - | - |
- - kWh |
- - kW-months/year |
$27,420 8,309 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $964 Cost: $921 |
$588 | 28,136 | $376 | 102 | - | - | - | - |
$588 28,136 kWh |
$376 102 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,555 Cost: $4,500 |
$1,592 | 76,202 | $963 | 260 | - | - | - | - |
$1,592 76,202 kWh |
$963 260 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $175,000 Cost: $1,800 |
- | - | - | - | - | - | $175,000 | 57,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$175,000 57,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $2,825 Cost: - |
- | - | - | - | - | - | $2,825 | 18,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,825 18,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $1,525 Cost: - |
- | - | - | - | - | - | $1,525 | 12,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,525 12,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $210,289 Cost: $9,221 |
$2,180 | 104,338 | $1,339 | 362 | $27,420 | 8,309 | $179,350 | 87,000 | $2,180 104,338 kWh |
$1,339 362 kW-months/year |
$27,420 8,309 MMBtu |
$179,350 87,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,289 Cost: $7,421 |
$2,180 | 104,338 | $1,339 | 362 | $27,420 | 8,309 | $4,350 | 30,000 | $2,180 104,338 kWh |
$1,339 362 kW-months/year |
$27,420 8,309 MMBtu |
$4,350 30,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) |