Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1996 |
Principal Product | Edible Oils and Shortenings |
NAICS | n/a |
SIC | 2079 - Edible Fats And Oils, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 155 |
Plant Area (Sq.Ft.) | 55,000 |
Annual Production | 225,000,000 Pounds |
Production Hrs. Annual | 8,568 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $348,371 | 14,178,488 | kWh | $0.02 |
Electricity Demand | $194,385 | 27,679 | kW-months/year | $7.02 |
Natural Gas | $202,407 | 41,799 | MMBtu | $4.84 |
TOTAL ENERGY COSTS | $1,016,163 | |||
RECOMMENDED SAVINGS* | $222,286 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,626 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $4,677 Cost: $2,000 |
- | - | - | - | $4,677 | 966 | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,677 966 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,243 Cost: $40 |
$893 | 36,342 | $350 | 50 | - | - | - | - | - | - |
$893 36,342 kWh |
$350 50 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $591 Cost: $44 |
$425 | 17,292 | $166 | 24 | - | - | - | - | - | - |
$425 17,292 kWh |
$166 24 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $826 Cost: $18,690 |
$566 | 23,154 | $260 | 37 | - | - | - | - | - | - |
$566 23,154 kWh |
$260 37 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,949 Cost: $9,950 |
$4,228 | 172,040 | $1,721 | 239 | - | - | - | - | - | - |
$4,228 172,040 kWh |
$1,721 239 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $209,000 Cost: $330,000 |
- | - | - | - | - | - | $118,000 | 32,500,000 | $91,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$118,000 32,500,000 Tgal |
$91,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $222,286 Cost: $360,724 |
$6,112 | 248,828 | $2,497 | 350 | $4,677 | 966 | $118,000 | 32,500,000 | $91,000 | - | $6,112 248,828 kWh |
$2,497 350 kW-months/year |
$4,677 966 MMBtu |
$118,000 32,500,000 Tgal |
$91,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,626 Cost: $11,950 |
$4,228 | 172,040 | $1,721 | 239 | $4,677 | 966 | - | - | - | - | $4,228 172,040 kWh |
$1,721 239 kW-months/year |
$4,677 966 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes |