Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1996 |
Principal Product | Reconditioned Gasoline & Diesel Engines |
NAICS | n/a |
SIC | 3519 - Internal Combustion Engines, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 850 |
Plant Area (Sq.Ft.) | 369,000 |
Annual Production | 68,500 Pieces |
Production Hrs. Annual | 3,640 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $204,958 | 5,172,040 | kWh | $0.04 |
Electricity Demand | $106,061 | 17,287 | kW-months/year | $6.14 |
Natural Gas | $353,491 | 86,832 | MMBtu | $4.07 |
TOTAL ENERGY COSTS | $770,360 | |||
RECOMMENDED SAVINGS* | $138,274 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,995 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Solid Waste (haz) | By-product Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Solid Waste (haz) | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $21,995 Cost: $21,995 |
- | - | $21,995 | - | - | - | - | - | - | - |
- - kWh |
$21,995 - kW-months/year |
- - lb |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $659 Cost: $3,956 |
$436 | 11,137 | $223 | 36 | - | - | - | - | - | - |
$436 11,137 kWh |
$223 36 kW-months/year |
- - lb |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,100 Cost: $2,100 |
$1,300 | 32,825 | $800 | 130 | - | - | - | - | - | - |
$1,300 32,825 kWh |
$800 130 kW-months/year |
- - lb |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $104,000 Cost: - |
- | - | - | - | - | - | - | - | $104,000 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - lb |
$104,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $3,130 Cost: $1,500 |
- | - | - | - | $3,130 | 33,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,130 33,000 lb |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $6,390 Cost: - |
- | - | - | - | - | - | $6,390 | 10,400 | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$6,390 10,400 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $138,274 Cost: $29,551 |
$1,736 | 43,962 | $23,018 | 166 | $3,130 | 33,000 | $6,390 | 10,400 | $104,000 | - | $1,736 43,962 kWh |
$23,018 166 kW-months/year |
$3,130 33,000 lb |
$6,390 10,400 lb |
$104,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,995 Cost: $21,995 |
- | - | $21,995 | - | - | - | - | - | - | - | - - kWh |
$21,995 - kW-months/year |
- - lb |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Solid Waste (haz) | By-product Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Solid Waste (haz) | By-product Production |